GM8802F-2 Field Mounting Transmitter
GM8802-F2110101
23
40219
0218
Channel no.
2
zero
calibration without weights
Write zero millivolt value
;
Read zero
millivolt value.
40221
0220
Write gain millivolt when
Channel no.
2
gain calibration
without weights
Write both of command to finish
grain calibration
;
Read millivolt value and weight
individually which are input at
calibration without weights.
40223
0222
Write weight value when
Channel no.
2
gain calibration
without weights
Bit only read address
(
function code
:
01
)
0301
0300
Channel no.
1
stable sign
0
:
unstable
;
1
:
stable
0302
0301
Channel no.
1
normal /
overflow sign
0
:
normal
;
1
:
overflow
0303
0302
Channel no.
1
zero sign
0
:
nonezero
;
1
:
zero
0304
0303
Channel no.
1
positive /
minus sign
0
:
positive sign
;
1
:
minus sign
0305
0304
Channel no.
1 AD
error sign
0
:
AD normal
;
1
:
AD error
0306
0305
Channel no.
1 AD
start /
shut
0
:
AD shut
;
1
:
AD start
0307
0306
Channel no.
2
stable sign
0
:
unstable
;
1
:
stable
0308
0307
Channel no.
2
normal /
overflow sign
0
:
normal
;
1
:
overflow
0309
0308
Channel no.
2
zero sign
0
:
nonezero
;
1
:
zero
0310
0309
Channel no.
2
positive /
minus sign
0
:
positive sign
;
1
:
minus sign
0311
0310
Channel no.
2 AD
error sign
0
:
AD normal
;
1
:
AD error
0312
0311
Channel no.
2 AD
start /
shut
0
:
AD shut
;
1
:
AD start
Bit read and write(optional) address
(
function code
:
01
,
05
)
0401
0400
Channel no.
1
zero
calibration
Write
:
ON
for zero calibration
OFF
for no operation.
Read
:
1
for zero status
0
for nonezero status
0402
0401
Channel no.
2
zero
calibration
Write
:
ON
for zero calibration
OFF
for no operation.
Read
:
1
for zero status
0
for nonezero status
0403
0402
Reserve
Write operation
:
Ineffective, and
return error message.
Read operation
:
read fixed
0
www.zemicusa.info