SRM-6 Operation & Diagnostics
SRM-6 Diagnostics
3-8
SC SRM-6 Multiplexer
076R176-000
Installation & Operation Manual
Issue 1
Diagnostics Procedure
1. At the Diagnostics screen, press
1
, then press
Enter
.
A highlight appears at the Aggregate Loopback field.
2. Use the UP arrow key to highlight the
Activate
option, then press
Enter
.
3. Type
S
to save the configuration to the unit. This starts the Aggregate Loopback test.
4. To terminate the test in progress, type
1
to select the Aggregate Loopback field, then press
Enter
. Use the UP arrow key to highlight the
Terminate
option, then press
Enter
.
5. Type
S
to save the configuration to the unit. This stops the test in progress.
Figure 3-1
Aggregate Loopback Data Path
Note
If erros are injected from the local DTE (central site), the errors are received on the local DTE and are also
passed through to the remote DTE.
CENTRAL SITE
VF 4-wire
Leased Line
DTE 1
DTE 2
DTE 3
DTE 4
DTE 5
DTE 6
SRM-6 MUX
SC V.F28.8
MODEM
SCM
REMOTE SITE
SRM-6 MUX
SC V.F28.8
MODEM
SCM
UP TO
6 DTEs
Aggregate
Loopback
Содержание 076P054-001
Страница 43: ......