Setting Card Options
The SRM-6 has four user-configurable option jumpers, X3, X4, X5 and X6, which configure the
DB-25 aggregate interface at the rear of the shelf for RS-232 or RS-530 mode.
shows
jumper locations and the default RS-232 setting. Note that option jumper X7 is reserved for future
use and will not affect SRM-6 operation.
Note
Refer to the corresponding manuals to set card options for the companion cards.
Figure 2-1
SRM-6 Option Jumpers
076P054-601
SRM-6
INS
TM
ON
AM
SYNC
ET
1
2
3
4
5
6
SD
RD
RS232
X3
530
RS232
X4
530
RS232
X5
530
RS232
X6
530
X7