SRM-6 Operation & Diagnostics
SRM-6 Diagnostics
076R176-000
SC SRM-6 Multiplexer
3-7
Issue 1
Installation & Operation Manual
SRM-6 Diagnostics
At the SRM-6 Main Menu, press
2
and then press
Enter
to access the SRM-6 Diagnostics
screen. The Aggregate Loopback test, activated/terminated from this screen, loops aggregate
transmit data from the DTE to receive data to the DTE.
and the associated illustration describes the menu selections.
shows the aggregate loopback data path.
Special Considerations
For this loopback, a timing source is required which can be supplied by DTE (TT) timing, or by a
device connected to the aggregate DTE port for ST timing.
Table 3-6
Diagnostics
Selection
Description
[1] Aggregate Loopback
Sets the unit to Activate the aggregate loopback test, or
Terminates a test in progress. Data is sent back to the connected
DTE.
[S] Save
Saves the setting to the unit and either activates the aggregate
loopback test, or terminates a test in progress.
[0] Return to Main Menu
Exits the Diagnostics menu and returns to the SRM-6 Main Menu.
SRM-6 Diagnostics
[1] Aggregate Loopback : Terminate
No Test in Progress
[S] Save Selection
[0] Return to Main Menu
Select: [ ]