1-800-345-8207
32
ALARM LIGHT
ALARM HORN WITH
SILENCER MODULE
L1
L2
L3
GND
M
208-230/460V, 3 PH, 60 HZ
G
CR-1
R
F1
F2
CR-1
COMPRESSOR
AUX. CONTACT
13
14
A2
A1
96
95
CONTROL
POWER LIGHT
COMPRESSOR
CONTACTOR
NITROGEN
SOLENOID
OVERLOADS
CONTACTOR
1
2
3
7
5
6
OVERLOAD OL-1
4
DRAIN
TEST
BUTTON
NITROGEN PRODUCTION
LIGHT
12
11
N.O.
N.O.
8
9
ALARM TERMINALS
CUSTOMER
CONNECTIONS
DRAIN
TEST
BUTTON
FILTER DRAIN
SOLENOID
AIR TANK
DRAIN
SOLENOID
COMPRESSOR
MOTOR
10
Q1
Q2
Q3
Q4
L1
N
I1
I2
I3
I4
I5
I6
I7
I8
PLC CONTROLLER
L
N
+
-
24 VDC POWER SUPPLY
+1
+5
-6
-2
15
14
13
POWER FAULT ALARM RELAY
CUSTOMER CONNECTIONS
(RELAY SOCKET SCREW TERMINALS )
NOTES: 1.GROUND MOTOR, PRESSURE SWITCHES, AND SOLENOID COILS
2. FIELD WIRING FOR NGP-2200D (SEE MANUAL)
SW-1
BYPASS VALVE
SWITCH
G
R-1
A2
A1
POWER STATUS
RELAY
SEE
NOTE 2
SEE
NOTE 2
SEE
NOTE 2
3
4
NITROGEN GENERATOR
WIRING DIAGRAM "LABEL"
208-230, 460V/3PH/60HZ
MODEL: NGP-500D THRU NGP-2200D
Drawing File\Nitrogen Generators\Non-Certified Versions\Wiring Diagrams\Air-N2 Tank Design\G-215336 Wiring Diagram, Cabinet
Label, Models NGP-500D thru NGP-2200D, Three Phase, 208-230, 460V
DRAWN: EMD
CHECKED: BLE - 10/16/15
DRAWING #: G-215336
REV. 2
PS-2
(60-75 PSI)
PS-1
(85-100 PSI)
DISCONNECT SWITCH, BRANCH CIRCUIT PROTECTION
AND/OR OVERLOAD RELAY TO BE PROVIDED BY INSTALLER
(SEE MANUAL FOR SIZING)
CR-1
OL-1
SOL-1
SOL-2
SOL-3
PB-1
PB-2
LT-3
HN-1
LT-1
R-1
LT-2
PWR-1