Generac Power Systems RXSW400A3CUL Скачать руководство пользователя страница 5

Introduction and Safety

Automatic Transfer Switch Owner’s Manual

1

Section 1: Introduction and Safety

Introduction

Thank you for purchasing a Generac Power Systems Inc.
product. This unit has been designed to provide high
performance, efficient operation, and years of use when
maintained properly. 

Read This Manual Thoroughly

If any section of this manual is not understood, contact
the nearest Independent Authorized Service Dealer
(IASD) or Generac Customer Service at 1-888-436-3722
(1-888-GENERAC), or visit 

www.generac.com

 for start-

ing, operating, and servicing procedures. The owner is
responsible for proper maintenance and safe use of the
unit.
SAVE THESE INSTRUCTIONS for future reference. This
manual contains important instructions that must be fol-
lowed during placement, operation, and maintenance of
the unit and its components. Always supply this manual
to any individual that will use this unit.

The information in this manual is accurate based on
products produced at the time of publication. The manu-
facturer reserves the right to make technical updates,
corrections, and product revisions at any time without
notice.

Safety Rules

The manufacturer cannot anticipate every possible cir-
cumstance that might involve a hazard. The alerts in this
manual, and on tags and decals affixed to the unit, are
not all inclusive. If using a procedure, work method, or
operating technique that the manufacturer does not spe-
cifically recommend, verify that it is safe for others and
does not render the equipment unsafe.
Throughout this publication, and on tags and decals
affixed to the unit, DANGER, WARNING, CAUTION, and
NOTE blocks are used to alert personnel to special
instructions about a particular operation that may be
hazardous if performed incorrectly or carelessly. Observe
them carefully. Alert definitions are as follows:

NOTE: 

Notes contain additional information important to

a procedure and will be found within the regular text of
this manual.

These safety alerts cannot eliminate the hazards that
they indicate. Common sense and strict compliance with
the special instructions while performing the action or
service are essential to preventing accidents.

Electrical Hazards

(000100a)

WARNING

Consult Manual. Read and understand manual
completely before using product. Failure to 
completely understand manual and product
could result in death or serious injury.

(000001)

DANGER

Indicates a hazardous situation which, if not avoided, 
will result in death or serious injury.

(000002)

WARNING

Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.

(000003)

CAUTION

Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.

(000129)

DANGER

Electrocution. High voltage is present at 
transfer switch and terminals. Contact with live 
terminals will result in death or serious injury.

 

(000104)

DANGER

Electrocution. Water contact with a power 
source, if not avoided, will result in death 
or serious injury.

(000145)

DANGER

Electrocution. In the event of electrical accident,  
immediately shut power OFF. Use non-conductive  
implements to free victim from live conductor. Apply  
first aid and get medical help. Failure to do so will  
result in death or serious injury

.

Содержание RXSW400A3CUL

Страница 1: ...AC COM 1 888 GENERAC 888 436 3722 Para espa ol visita http www generac com service support product support lookup Pour le fran ais visiter http www generac com service support product support lookup S...

Страница 2: ...ii Automatic Transfer Switch Owner s Manual 000393a WARNING CANCER AND REPRODUCTIVE HARM www P65Warnings ca gov...

Страница 3: ...ner Load 11 Auxiliary Contacts 13 Fault Current Label 13 Section 4 Operation Functional Tests and Adjustments 15 Manual Operation 15 Close to Normal Source Side 16 Close to Standby Source Side 16 Retu...

Страница 4: ...iv Automatic Transfer Switch Owner s Manual This page intentionally left blank...

Страница 5: ...unsafe Throughout this publication and on tags and decals affixed to the unit DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation th...

Страница 6: ...ng and connections to unit Failure to follow proper installation requirements could result in death serious injury and equipment or property damage 000120 CAUTION Equipment damage Verify all conductor...

Страница 7: ...000213 DANGER Electrocution Only authorized personnel should access transfer switch interior Transfer switch doors should be kept closed and locked Failure to do so will result in death or serious in...

Страница 8: ...Introduction and Safety 4 Automatic Transfer Switch Owner s Manual This page intentionally left blank...

Страница 9: ...UL listed transfer switch has locking provisions for the utility entry cabinet In addition it has a lockout tagout provision for the service entrance circuit breaker Transfer Switch Mechanism See Figu...

Страница 10: ...s affixed to the equipment The following publications outline the safe use of transfer switches Canadian Electrical Code CE CSA C22 1 NFPA 70E Standard for Electrical Safety In The Workplace UL CUL 10...

Страница 11: ...top priorities then use additional SMMs as the remaining priorities A SMM can share a priority with an A C priority on the SACM provided the generator is sized to handle the combined surge load from b...

Страница 12: ...General Information 8 Automatic Transfer Switch Owner s Manual This page intentionally left blank...

Страница 13: ...to it Mount the switch vertically to a rigid supporting structure To pre vent switch distortion level all mounting points If neces sary use washers behind mounting holes to level the unit Open Enclosu...

Страница 14: ...ent to which they will be subjected based on the 75 C column of tables charts etc used to size con ductors The installation must comply fully with all appli cable codes standards and regulations Knock...

Страница 15: ...tor within the equipment cable or conduit See NEC 300 3 C 1 Connecting SACM See Figure 3 3 The SACM can control an air conditioner 24 VAC directly Control of Air Conditioner Load 1 Route the thermosta...

Страница 16: ...t 2 D Air Conditioner 2 E Thermostat 3 F Air Conditioner 3 G Thermostat 4 H Air Conditioner 4 T1 fused Battery Charge N1 fused Utility Sense N2 fused Utility Sense 0 Ground 194 12 VDC 23 Transfer Cont...

Страница 17: ...transfer equipment be field marked on the exterior of the transfer equipment For NEC compliance verify the required short circuit current rating of the transfer switch before installation The com ple...

Страница 18: ...Installation 14 Automatic Transfer Switch Owner s Manual This page intentionally left blank...

Страница 19: ...Operation See Figure 4 1 A manual handle A is shipped with the transfer switch Manual operation must be checked BEFORE the transfer switch is operated electrically Proceed as follows to check manual o...

Страница 20: ...MM manufac turer s literature for additional information Utility Voltage Checks 1 Turn ON the UTILITY power supply to the transfer switch with whatever means provided such as the UTILITY main line cir...

Страница 21: ...transfer switch 5 Set transfer switch utility service disconnect circuit breaker to ON CLOSED 6 Set generator main circuit breaker to ON 7 Select AUTO on generator panel The system is now ready for au...

Страница 22: ...e test pushbutton will work when the ATS is in the utility or the generator position Figure 4 2 Test Pushbutton and Fuse Removal Installation Tool 1 Turn on the utility supply to the ATS 2 Verify mana...

Страница 23: ...nual 19 Section 5 Drawings and Diagrams Installation Drawing No 0K2438 A 400A Service Entrance Rated PP PP PP PP PP PP PP 3 2 86720 5 6833 2 7 21 PP 127 25 5 5 7 1 6 21 8 76 0867 17 5 2 1 5 20321 176...

Страница 24: ...rams 20 Automatic Transfer Switch Owner s Manual Interconnection Drawing No 10000041110 Part 1 of 2 Liquid Cooled Generator GROUP G INTERCONNECTION DIAGRAM ID 400A CUL SACM DRAWING 10000041110 REVISIO...

Страница 25: ...ings and Diagrams Automatic Transfer Switch Owner s Manual 21 No 10000041110 Part 2 of 2 Air Cooled Generator GROUP G INTERCONNECTION DIAGRAM ID 400A CUL SACM DRAWING 10000041110 REVISION A DATE 07 18...

Страница 26: ...s 22 Automatic Transfer Switch Owner s Manual Schematic and Wiring Diagram No 10000041100 Part 1 of 2 Schematic Diagram SCHEMATIC DIAGRAM SERVICE ENTRANCE W SMART AC MODULE DRAWING 10000041100 REVISIO...

Страница 27: ...awings and Diagrams Automatic Transfer Switch Owner s Manual 23 No 10000041100 Part 2 of 2 Wiring Diagram WIRING DIAGRAM SERVICE ENTRANCE W SMART AC MODULE DRAWING 10000041100 REVISION A DATE 07 31 20...

Страница 28: ...Drawings and Diagrams 24 Automatic Transfer Switch Owner s Manual This page intentionally left blank...

Страница 29: ...Drawings and Diagrams Automatic Transfer Switch Owner s Manual 25 This page intentionally left blank...

Страница 30: ...Drawings and Diagrams 26 Automatic Transfer Switch Owner s Manual This page intentionally left blank...

Страница 31: ......

Страница 32: ...ights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W29290...