SPECIFICATIONS

GENERATOR

Type ............................................................................. Synchronous
Rotor Insulation ................................................................... Class H
Stator Insulation .................................................................. Class H
Total Harmonic Distortion ......................................................< 3.5%
Telephone Interference Factor (TIF) ..........................................< 50
Alternator Output Leads 3-phase ........................................... 4-wire
Bearings .........................................................................Sealed Ball
Coupling .......................................................................Flexible Disc
Load Capacity (Standby Rating) ............................................50kW*
*

  NOTE: Generator rating and performance in accordance with ISO8528-5, BS5514, SAE J1349, 

ISO3046 and DIN 6271 Standards. KW rating is based on LPG fuel and may derate with natural 

gas.

Excitation System ....................................................................Direct
Generator Output Voltage/kW - 60 Hz 

kW 

Amp  CB Size

  120/240V, 1-phase, 1.0 pf 

50 

208 

225

  120/208V, 3-phase, 0.8 pf 

50 

173 

200

  277/480V, 3-phase, 0.8 pf 

50 

75 

90

Generator Locked Rotor KVA Available @ Voltage Dip of 35%
  Single-phase or 208 3-phase ............................................. 92 KVA
  480V, 3-phase .................................................................. 105 KVA

ENGINE

Make ................................................................................... Generac
Model ...................................................................................... V-type
Cylinders and Arrangement ............................................................ 6
Displacement ....................................................................... 3.0  Liter
Bore ...................................................................................... 3.55  in.
Stroke ..................................................................................... 3.1  in.
Compression Ratio ...............................................................9.3-to-1
Air Intake System ...............................................Naturally Aspirated
Valve Seats ....................................................................... Hardened
Lifter Type .......................................................................... Hydraulic

Engine Parameters

Rated Synchronous RPM ..............................................60 Hz, 3600
HP at rated kW ..................................................................60 Hz, 88

Exhaust System

Exhaust Flow at Rated Output 60 Hz .................................. 494 cfm
Exhaust Temperature at Rated Output ................................ 1050° F

Combustion Air Requirements

Flow at rated power, 60 Hz ................................................. 176 cfm

Governor

Type .................................................................................. Electronic
Frequency Regulation ...................................................Isochronous
Steady State Regulation ........................................................± 1/2%
Adjustments:
  Speed ............................................................................ Selectable

‹

‹

Engine Lubrication System

Type of Oil Pump ...................................................................... Gear
Oil Filter .............................................................Full Flow, Cartridge
Crankcase Oil Capacity ....................................................4 U.S. qts.

COOLING SYSTEM

Type ....................................................................................... Closed
Water Pump .................................................................... Belt Driven
Fan Speed ................................................................................ 2180
Fan Diameter .....................................................................22 inches
Fan Mode ................................................................................ Puller
Air Flow (inlet air including alternator and
  combustion air) .......................................................... 3280 ft3/min.
Coolant Capacity ........................................................ (2.5 U.S. gal.)
Heat Rejection to Coolant ..........................................226,000 Btu/h
Maximum Operating Air Temp. on Radiator ..............60° C (150° F)
Maximum Ambient Temperature ................................50° C (140° F)

FUEL SYSTEM

Type of Fuel ......................................... Natural Gas, Propane Vapor
Carburetor ...................................................................... Down Draft
Secondary Fuel Regulator .................................................Standard
Fuel Shut-off Solenoid ........................................................Standard
Operating Fuel Pressure  ...................... 5 in. - 14 in. Water Column

Fuel Consumption - ft

3

/hr(Natural Gas/LPV)

 Exercise 

25% 

50% 

75% 

100%

 Cycle 

Load 

Load 

Load  Load

 123/49.3  216/81.2  417/167.8  581/233 803/322.7

*

   Engine is not field convertible between natural gas and propane. Jet size and ignition timing are 

factory set for the specific fuel.

ELECTRICAL SYSTEM

Battery Charge Alternator ............................................12V, 30 Amp
Static Battery Charger ............................................................2 Amp
Recommended Battery ................................................ 24F 525CCA
System Voltage .....................................................................12 Volts

Voltage Regulator

Type .................................................................................. Electronic
Sensing ........................................................................ Single-phase
Regulation ................................................................................± 1%
Features .................................................V/F Adjustable, Adjustable
 

Voltage and Gain LED Indicators

Power Adjustment for Ambient Conditions

Temperature Deration
  3% for every 10° C above °C ..................................................... 25
  1.65% for every 10° above °F .................................................... 77
Altitude Deration
  1% for every 100 m above m ................................................... 183
  3% for every 1000 ft. above ft. ................................................. 600

Controller .................................................R-100

‹

‹

‹

6-1

Standby Generator Sets

Specifications

GenSpec004  Rev.

 C  11/05

Содержание QT05030AVAN

Страница 1: ...STANDBY GENERATOR OWNER S MANUAL This manual should remain with the unit A new standard of reliability Serial Number QT 3 0L 50kW Models Cover007 Rev A 10 05 Part No 0F3527A...

Страница 2: ...or to Initial Start up 8 1 Initial Inspection for QT Genset Start up 8 1 Start up Inspection 8 2 OPERATION 9 1 Generator Control and Operation 9 1 Operating Unit with Manual Transfer Switch 9 1 Engine...

Страница 3: ...his symbol points out potential fire hazard This symbol points out potential electrical shock hazard The operator is responsible for proper and safe use of the equip ment The manufacturer strongly rec...

Страница 4: ...n must be provided This should be considered prior to installing the generator The unit should be positioned to direct exhaust gasses safely away from any building where people animals etc will not be...

Страница 5: ...mpt to free the victim from the live conductor AVOID DIRECT CONTACT WITH THE VICTIM Use a nonconducting implement such as a dry rope or board to free the victim from the live conductor If the victim i...

Страница 6: ...service ordering parts or seeking information Identification Code Use this code to obtain important information about the generator For example if the code is M Designates generators capable of paral...

Страница 7: ...een properly serviced with the recom mended oil may result in an engine failure NOTE If not already equipped it is strongly recommended to use the optional Cold Weather Start Kit for temperatures belo...

Страница 8: ...OFF MANUAL switch must be turned to OFF and then back to AUTO OVERCRANK SHUTDOWN After a prespecified duration of cranking this function ends the cranking if the engine has failed to start The overcr...

Страница 9: ...ers a building a primary regulator is needed The natural gas supplier may or may not supply such a regulator It is the responsibility of the gas supplier to make sure sufficient gas pressure is availa...

Страница 10: ...2 Adjustments Speed Selectable Engine Lubrication System Type of Oil Pump Gear Oil Filter Full Flow Cartridge Crankcase Oil Capacity 4 U S qts COOLING SYSTEM Type Closed Water Pump Belt Driven Fan Spe...

Страница 11: ...l cold weather kit part number 0F6148 is recommended The kit includes Battery Warmer 4 Junction Box with hardware 6 qt pack 5W 30 synthetic oil engine Figure 1 Interconnections 6 2 Standby Generator S...

Страница 12: ...ach circuit breaker terminal is 240V The rated voltage between each circuit breaker terminal and the neutral point 00 is 120V Figure 7 1 Four lead Single phase Stator ALTERNATOR POWER WINDING CONNECTI...

Страница 13: ...ator gearbox if so equipped prior to initial use and at the intervals indicated by the Service Schedule The recommended oil is SAE 90 gear lubricant Also if the engine is equipped with a mechanical go...

Страница 14: ...h to the MANUAL position The engine should now crank and start Check voltage at the generator terminals For 3 phase units check phase rotation at the transfer switch terminals The generator phase rota...

Страница 15: ...the utility source main line circuit breaker Set the transfer handle to its UTILITY NORMAL position with load circuits connected to the utility power supply Set the generator s main line circuit brea...

Страница 16: ...aust system parts from this product get extremely hot and remains hot after shut down High grass weeds brush leaves etc must remain clear of the exhaust Such mate rials may ignite and burn from the he...

Страница 17: ...uired INSPECT ENGINE GOVERNOR Visually inspect electronic governor nDo not attempt to adjust the governor Only qualified service facilities should adjust the governor Excessively high operating speeds...

Страница 18: ...rized Service Dealer That dealer will use dry low pressure air to clean internal windings Parts inside the control console should be cleaned and inspected at this time as well Finally have the insulat...

Страница 19: ...it from the generator for recharging nBe sure the AUTO OFF MANUAL switch is set to the OFF position before connecting the battery cables If the switch is set to AUTO or MANUAL the generator can crank...

Страница 20: ...o standby setup for normal operation when required 2 A wear in service inspection of the generator set to insure it is ready to operate and carry the load when required and to identify any potential p...

Страница 21: ...heck the engine coolant level Adjust as necessary 4 Check the engine coolant thermal protection level Correct as necessary 5 Check the natural gas delivery system for leaks and correct pressure on gas...

Страница 22: ...e engine valve clearance lash Adjust as necessary 12 Visually inspect the unit looking for leaks wear or damage loose connections or components and corrosion Correct as necessary 13 Test the engine an...

Страница 23: ...s not enough for at least 2 hours looking for leaks loose connections or components and abnormal operating conditions Correct as necessary 19 Perform an engine oil analysis send a sample to a lab for...

Страница 24: ...as recommended in SPECIFICATIONS Engine starts then shuts down 1 Engine oil level is low 1 Check oil and add oil as needed 2 Engine is overheated 2 Check cooling system for leaks 3 Defective Low Oil...

Страница 25: ...Notes...

Страница 26: ......

Страница 27: ...B SHORT STND C 0D5552 1 CB 0050A 3P 480V S ED4 LL 0D5553 CB 0060A 3P 480V S ED4 LL 0D5554 CB 0070A 3P 480V S ED4 LL 0D5556 CB 0090A 3P 480V S ED4 LL 0D9693 CB 0125A 3P 480V S ED4 LL D 0F0492 1 INSULAT...

Страница 28: ......

Страница 29: ...APTOR 1 W W CB 2 TERMINAL COVER CB X 0G3259 1 DECAL TERMINAL SHOCK HZD BI 7 UL CIRCUIT BREAKER 400AF A 0F4187 1 COVER CB C2 C4 400AF C 0F4166 REF CIRCUIT BREAKERS 400A FRAME D 0F1733 1 DECAL CUSTOMER...

Страница 30: ......

Страница 31: ...HSB 9 0F6125 1 GUARD REAR BEARING CARRIER CPL 10 0F2689 1 RING PRESSURE 390 STATOR CAN 11 023454 1 KEY WOODRUFF E 12 077043F 1 CONDUIT FLEX 1 1 4 30 LG 13 04576100BU 4 STUD M14 2 0 570 G5 ZINC 50KW 04...

Страница 32: ......

Страница 33: ...F6305 3 SEAL COVER 3 18X12 7X382 27 0F6305A 1 SEAL COVER 3 18X12 7X283 28 0F5886 3 SCREW HHPM M5 0 8 X 12 29 051713 12 WASHER FLAT M5 30 049226 12 WASHER LOCK M5 31 0F5752F 1 RES WW 15R 5 25W QK CONN...

Страница 34: ......

Страница 35: ...22097 1 WASHER LOCK M6 1 4 14 022473 1 WASHER FLAT M6 1 4 ZINC 15 049813 1 NUT HEX M6 1 0 G8 YEL CHR 16 022261 1 WASHER SHAKEPROOF INT 3 8 17 0F2230 2 SUPPORT ENGINE 3 9L LH RH SD 0E8824 2 STAMPING EN...

Страница 36: ......

Страница 37: ...3 8 M10 ZINC 7 050331A 1 BATT POST COVER RED 8 050331 1 BATT POST COVER BLK 9 03880400AA 1 CABLE BATT RED 1 X 44 00 10 038805T 1 CABLE BATT BLK 1 X 40 00 11 045771 1 NUT HEX M8 1 25 G8 YEL CHR 12 022...

Страница 38: ......

Страница 39: ...1 0 X 16 G8 8 31 022097 4 WASHER LOCK M6 1 4 32 022473 4 WASHER FLAT 1 4 M6 ZINC 33 057765 1 ADAPTER M14 1 50 X 3 8 NPT 34 040976 8 SCREW SHC M8 1 25 X 20 G12 9 35 022129 12 WASHER LOCK M8 5 16 36 022...

Страница 40: ......

Страница 41: ...G8 8 42 082774 1 KEY WOODRUFF 4 X 19D 43 0F2812 1 HOSE LOWER RADIATOR 44 0F6726 1 HOSE UPPER RAD CPL C4 45 049813 4 NUT HEX M6 X 1 0 G8 YEL CHR 46 0F2835 1 INNER DISCHARGE DUCT C4 48 0C2454 6 SCREW T...

Страница 42: ......

Страница 43: ...4 7 047411 4 SCREW HHC M6 1 0 X 16 G8 8 8 0F5418 1 ELEMENT AIR FILTER 9 0F6323 1 PLATE AIR CLEANER TOP 3 9L 10 037561 1 NUT WING 1 4 20 NYLK 11 074008 1 WASHER M10 LOCK 12 070264 1 WASHER FLAT M10 13...

Страница 44: ......

Страница 45: ...TER 3 0L FORD BOSCH 19 0E6586 1 GASKET BOSCH 32 20 0E4394 1 ACTUATOR BOSCH 40 GOVERNOR 21 0F3857 1 REDUCER RUBBER 3 0 2 00 22 0F3885 1 MIXER 40 60MM ACTUATOR ASSY 23 0G3167 2 O RING 2 3 4 X 3 32 X 2 1...

Страница 46: ......

Страница 47: ...ON SPLITTER 33 0F3760E 3 INSULATION LOWER SPLITTER 34 0F5048D 4 VISE ACTION LATCH SLOTTED CIR 35 0E5968 1 GASKET EXTRUDED TRIM 374 64 LG 36 0F3760J 1 INSULATION DISCHARGE FRONT 37 0F3890A 9 RETAINER I...

Страница 48: ......

Страница 49: ...4 SCREW HHC 3 8 16 X 2 SS FTH 14 0E8816 2 EXHAUST FLANGE 2 PIPE 15 0F4505 REF GLASS PACK 23 5 LG 2 5 IN OUT 16 022097 2 WASHER LOCK M6 1 4 17 0C2454 REF SCREW THF M6 1 X 16 N WA Z JS 18 0F4367 REF HE...

Страница 50: ......

Страница 51: ......

Страница 52: ......

Страница 53: ......

Страница 54: ......

Страница 55: ......

Страница 56: ......

Страница 57: ......

Страница 58: ......

Страница 59: ......

Страница 60: ......

Страница 61: ......

Страница 62: ...Notes...

Страница 63: ...Notes...

Страница 64: ...e caused by contaminated fuels oils coolants antifreeze or lack of proper fuels oils or coolants antifreeze 4 Units sold rated or used for Prime Power Trailer Mounted or Rental Unit applications as Ge...

Отзывы: