6

7000EXL Extended Life Generator

GROUNDING THE

GENERATOR

The National Electrical Code requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground. Local
electrical codes may also require proper grounding of the
unit. For that purpose, a GROUNDING WING NUT is
provided on the generator end (Figure 3).

Generally, connecting a No. 12 AWG (American Wire
Gauge) stranded copper wire to the grounding wing nut
and to an earth–driven copper or brass grounding rod
(electrode) provides adequate protection against electrical
shock. Be careful to keep the grounding wire attached after
connecting the stranded copper wire. However, local codes
may vary widely. Consult with a local electrician for
grounding requirements in your area.

Properly grounding the generator helps prevent electrical
shock if a ground fault condition exists in the generator or
in connected electrical devices, especially when the unit is
equipped with a wheel kit. Proper grounding also helps
dissipate static electricity, which often builds up in
ungrounded devices.

OPERATING THE

GENERATOR

CAUTION!

NEVER start or stop unit with

electrical loads connected AND with the connected
devices turned ON.

IMPORTANT: Always unplug the battery float charger
before starting the generator.

Starting the Engine

Disconnect all electrical loads from the generator. Follow
these start instruction steps in numerical order:

1.

Turn the fuel valve to the “On” position (Figure 4).

2.

Make sure the Idle Control switch is in “Off” position
(Figure 5).

3.

Set the Run/Stop switch to “Run” position (Figure 6).

4.

Place the choke lever in the “Full” choke position
(Figure 7).

Figure 4 — Fuel Shut-off Valve

Figure 5 — Idle Control Switch

Figure 6 — Run/Stop Switch

Figure 7 — Choke Positions

Figure 3 — Grounding Wing Nut

Grounding
Wing Nut

Fuel Valve  shown  in

the “On” position

Содержание 7000exl

Страница 1: ...0 Troubleshooting D pannage 13 32 Schematic Sch ma 14 Wiring Diagram Circuit de C blage 15 Replacement Parts Pi ces de Rechange 16 19 Notes Remarques 31 33 34 Garantie 35 Warranty Last Page Generator...

Страница 2: ...rnia to cause cancer birth defects or other reproductive harm WARNING In the State of California a spark arrester is required by law Section 4442 of the California Public Resources Code Other states m...

Страница 3: ...lectrolyte fluid contains acid and is extremely caustic Contact with battery fluid will cause severe chemical burns DANGER DO NOT touch hot surfaces Allow equipment to cool before touching Running eng...

Страница 4: ...rting a cold engine Circuit Breakers AC The 120 Volt AC 20 Amp duplex receptacle is provided with push to reset circuit breakers to protect the generator against electrical overload Double Pole Circui...

Страница 5: ...fuel tank when engine is running or hot Allow unit to cool for two minutes before refueling DO NOT light a cigarette or smoke when filling the fuel tank WARNING DO NOT overfill the fuel tank Always a...

Страница 6: ...ps prevent electrical shock if a ground fault condition exists in the generator or in connected electrical devices especially when the unit is equipped with a wheel kit Proper grounding also helps dis...

Страница 7: ...d generator Move run stop switch to Stop Close the fuel shut off valve Operating Automatic Idle Control This switch is designed to greatly improve fuel economy When this switch is turned ON the engine...

Страница 8: ...Enclosure should hold enough heat created by the generator to prevent problems CAUTION NEVER run unit indoors DO NOT enclose generator any more than shown Remove generator from shelter when temperatu...

Страница 9: ...or can damage it or cause serious injuries 240 Volt loads powered through this outlet should not exceed 29 2 Amps of current draw 120 Volt AC 30 Amp Locking Receptacle Use a NEMA L5 30 plug with this...

Страница 10: ...erator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each addi...

Страница 11: ...e consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slot...

Страница 12: ...ool for a sufficient time before placing the cover on the unit Engine Storage See engine owner s manual for instructions Other Storage Tips To prevent gum from forming in fuel system or on essential c...

Страница 13: ...ark plug wire not connected to spark plug 7 Bad spark plug 8 Water in gasoline 9 Overchoking 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 13 Fai...

Страница 14: ...14 7000EXL Extended Life Generator SCHEMATIC...

Страница 15: ...7000EXL Extended Life Generator 15 WIRING DIAGRAM...

Страница 16: ...16 7000EXL Extended Life Generator EXPLODED VIEW ALTERNATOR...

Страница 17: ...7000EXL Extended Life Generator 17 EXPLODED VIEW FRAME...

Страница 18: ...CAL Heat Shield 51 56893GS 5 SCREW 52 84132GS 1 ASSY Power Regulator 53 67022GS 1 GROMMET Rubber Item Part Qty Description 54 SRV66825DGS 1 CARRIER Rear Bearing 55 86494GS 1 SCREW Wing 56 23762GS 4 WA...

Страница 19: ...AGS 1 BREAKER Circuit 30A 2P 11 75207GS 2 BREAKER Circuit 20A 12 23365GS 6 WASHER Shakeproof 13 68868GS 1 OUTLET 120V 30A Lock Item Part Qty Description 14 43437GS 1 OUTLET 120 240V 30A Lock 15 68759G...

Страница 20: ...reproduction AVERTISSEMENT Dans l tat de Californie un pare tincelles est requis par la loi section 4442 du Code des ressources publiques de Californie D autres tats ont des lois similaires Les lois f...

Страница 21: ...ctrolyte de l accumulateur contient de l acide et est extr mement caustique Le contact avec le liquide de l accumulateur provoquera de graves br lures chimiques DANGER NE TOUCHEZ PAS les surfaces chau...

Страница 22: ...te le moteur Interrupteur de starter Utilis lorsque vous faites un d marrage froid du moteur Pot d chappement avec arr teur d tincelles Le pot d chappement diminue le bruit du moteur est quip d un cra...

Страница 23: ...e remplir le r servoir N ALLUMEZ PAS une cigarette ou ne fumez pas lorsque vous remplissez le r servoir AVERTISSEMENT NE PAS trop remplir le r servoir Toujours laisser de la place pour la dilatation d...

Страница 24: ...roues Une bonne mise la terre peut galement aider la dissipation de l lectricit statique qui s amoncelle souvent dans les appareils sans mise la terre UTILISATION DU G N RATEUR ATTENTION NE JAMAIS d m...

Страница 25: ...a pour but d am liorer grandement l conomie en carburant Lorsque cet interrupteur est en MARCHE ON le moteur ne marchera sa vitesse lev e normale r gl e d avance que lorsqu une charge lectrique est br...

Страница 26: ...ments Le bo tier doit retenir suffisamment de chaleur g n r e par le g n rateur pour viter tout probl me ATTENTION NE FAITES JAMAIS fonctionner l appareil l int rieur N ENFERMEZ PAS le g n rateur plu...

Страница 27: ...dommager celui ci ou causer de graves blessures corporelles Les charges de 240Volts mises sous tension gr ce cette prise de doivent pas exc der 29 2 Amp res de courant Prise Verrouillage de 120 Volts...

Страница 28: ...u g n rateur se stabiliser le moteur tourne r guli rement et les dispositifs branch s fonctionnent correctement 4 Branchez et mettez la charge suivante en marche 5 De nouveau laissez le g n rateur se...

Страница 29: ...onnement propre et sec o celui l ne sera pas expos trop de poussi re de salet d humidit ou des vapeurs corrosives Les fentes de refroidissement par air du g n rateur ne doivent pas tre bouch es par de...

Страница 30: ...ture sur l unit Remisage du Moteur Voir les instructions sur la mani re de remiser correctement le moteur dans le manuel de l utilisateur du moteur Autres Id es de Remisage Pour viter la formation de...

Страница 31: ...31 7000EXL G n rateur Qui Dure Longtemps REMARQUES...

Страница 32: ...a de l eau dans l essence 9 Trop de starter 10 M lange de carburant trop riche 11 Soupape d admission bloqu e en position ouverte ou ferm e 12 Le moteur a perdu de sa compression 13 Batterie d fectue...

Страница 33: ...33 7000EXL G n rateur Qui Dure Longtemps REMARQUES...

Страница 34: ...7000EXL G n rateur Qui Dure Longtemps 34 REMARQUES...

Страница 35: ...ration un usage mauvais escient des n gligences un accident une surcharge une vitesse excessive un entretien inappropri une r paration ou un entreposage qui seront jug s par Generac Portable Products...

Страница 36: ...en subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in Generac Portable Products judgme...

Отзывы: