background image

8

7000EXL Extended Life Generator

• Connect battery charge cable clamp with black handle

to the negative (–) battery terminal (Figure 8).

• Start engine. Let the engine run while battery recharges.

• When battery has charged, shut down engine.

NOTE: Use an automotive hydrometer to test battery state
of charge and condition. Follow the hydrometer
manufacturer’s instructions carefully. Generally, a battery is
considered to be at 100% state of charge when specific gravity
of its fluid (as measured by hydrometer) is 1.260 or higher.

COLD WEATHER

OPERATION

Under certain weather conditions (temperatures below
40°F [4°C] and a high dew point), your generator may
experience icing of the carburetor and/or the crankcase
breather system.

Build a structure that will enclose three sides and the top
of the generator.

• Make sure entire muffler-side of generator is exposed.

Note that your generator may appear different from that
shown in Figure 9.

• Ensure a minimum of two feet clearance between open

side of box and nearest object.

• Face exposed end away from wind and elements.

• Enclosure should hold enough heat created by the

generator to prevent problems.

CAUTION

NEVER run unit indoors. DO NOT

enclose generator any more than shown. Remove
generator from shelter when temperature is above
40°F [4°C].

How to Use the Battery Charger

Use battery float charger jack to keep the starting battery
charged and ready for use. Battery charging should be done
in a dry location, such as inside a garage.

• Plug the charger into the unit’s “Battery Float Charger”

jack, which is located on the starter switch (Figure 10).
Plug battery charger into a 120 Volt AC wall receptacle.

• Unplug the charger from the unit and the wall outlet

when generator is being started and while it is in
operation.

• Keep this charger plugged in when generator is not in

use to prolong battery life.The charger has a built in
float equalizer and will not overcharge the battery, even
when plugged in for an extended period of time.

IMPORTANT: See “Battery Maintenance” on page 11 for
additional information.

RECEPTACLES

120 Volt AC, 20 Amp  Duplex

Receptacle

Each of these outlets is protected against overload by
20 Amp push-to-reset type circuit breakers (Figure 11).

Figure 10 — Battery Charger Jack

Figure 9 — Permanent Cold Weather Shelter

Wind

Figure 8 — Battery Connections

Содержание 7000exl

Страница 1: ...0 Troubleshooting D pannage 13 32 Schematic Sch ma 14 Wiring Diagram Circuit de C blage 15 Replacement Parts Pi ces de Rechange 16 19 Notes Remarques 31 33 34 Garantie 35 Warranty Last Page Generator...

Страница 2: ...rnia to cause cancer birth defects or other reproductive harm WARNING In the State of California a spark arrester is required by law Section 4442 of the California Public Resources Code Other states m...

Страница 3: ...lectrolyte fluid contains acid and is extremely caustic Contact with battery fluid will cause severe chemical burns DANGER DO NOT touch hot surfaces Allow equipment to cool before touching Running eng...

Страница 4: ...rting a cold engine Circuit Breakers AC The 120 Volt AC 20 Amp duplex receptacle is provided with push to reset circuit breakers to protect the generator against electrical overload Double Pole Circui...

Страница 5: ...fuel tank when engine is running or hot Allow unit to cool for two minutes before refueling DO NOT light a cigarette or smoke when filling the fuel tank WARNING DO NOT overfill the fuel tank Always a...

Страница 6: ...ps prevent electrical shock if a ground fault condition exists in the generator or in connected electrical devices especially when the unit is equipped with a wheel kit Proper grounding also helps dis...

Страница 7: ...d generator Move run stop switch to Stop Close the fuel shut off valve Operating Automatic Idle Control This switch is designed to greatly improve fuel economy When this switch is turned ON the engine...

Страница 8: ...Enclosure should hold enough heat created by the generator to prevent problems CAUTION NEVER run unit indoors DO NOT enclose generator any more than shown Remove generator from shelter when temperatu...

Страница 9: ...or can damage it or cause serious injuries 240 Volt loads powered through this outlet should not exceed 29 2 Amps of current draw 120 Volt AC 30 Amp Locking Receptacle Use a NEMA L5 30 plug with this...

Страница 10: ...erator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each addi...

Страница 11: ...e consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slot...

Страница 12: ...ool for a sufficient time before placing the cover on the unit Engine Storage See engine owner s manual for instructions Other Storage Tips To prevent gum from forming in fuel system or on essential c...

Страница 13: ...ark plug wire not connected to spark plug 7 Bad spark plug 8 Water in gasoline 9 Overchoking 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 13 Fai...

Страница 14: ...14 7000EXL Extended Life Generator SCHEMATIC...

Страница 15: ...7000EXL Extended Life Generator 15 WIRING DIAGRAM...

Страница 16: ...16 7000EXL Extended Life Generator EXPLODED VIEW ALTERNATOR...

Страница 17: ...7000EXL Extended Life Generator 17 EXPLODED VIEW FRAME...

Страница 18: ...CAL Heat Shield 51 56893GS 5 SCREW 52 84132GS 1 ASSY Power Regulator 53 67022GS 1 GROMMET Rubber Item Part Qty Description 54 SRV66825DGS 1 CARRIER Rear Bearing 55 86494GS 1 SCREW Wing 56 23762GS 4 WA...

Страница 19: ...AGS 1 BREAKER Circuit 30A 2P 11 75207GS 2 BREAKER Circuit 20A 12 23365GS 6 WASHER Shakeproof 13 68868GS 1 OUTLET 120V 30A Lock Item Part Qty Description 14 43437GS 1 OUTLET 120 240V 30A Lock 15 68759G...

Страница 20: ...reproduction AVERTISSEMENT Dans l tat de Californie un pare tincelles est requis par la loi section 4442 du Code des ressources publiques de Californie D autres tats ont des lois similaires Les lois f...

Страница 21: ...ctrolyte de l accumulateur contient de l acide et est extr mement caustique Le contact avec le liquide de l accumulateur provoquera de graves br lures chimiques DANGER NE TOUCHEZ PAS les surfaces chau...

Страница 22: ...te le moteur Interrupteur de starter Utilis lorsque vous faites un d marrage froid du moteur Pot d chappement avec arr teur d tincelles Le pot d chappement diminue le bruit du moteur est quip d un cra...

Страница 23: ...e remplir le r servoir N ALLUMEZ PAS une cigarette ou ne fumez pas lorsque vous remplissez le r servoir AVERTISSEMENT NE PAS trop remplir le r servoir Toujours laisser de la place pour la dilatation d...

Страница 24: ...roues Une bonne mise la terre peut galement aider la dissipation de l lectricit statique qui s amoncelle souvent dans les appareils sans mise la terre UTILISATION DU G N RATEUR ATTENTION NE JAMAIS d m...

Страница 25: ...a pour but d am liorer grandement l conomie en carburant Lorsque cet interrupteur est en MARCHE ON le moteur ne marchera sa vitesse lev e normale r gl e d avance que lorsqu une charge lectrique est br...

Страница 26: ...ments Le bo tier doit retenir suffisamment de chaleur g n r e par le g n rateur pour viter tout probl me ATTENTION NE FAITES JAMAIS fonctionner l appareil l int rieur N ENFERMEZ PAS le g n rateur plu...

Страница 27: ...dommager celui ci ou causer de graves blessures corporelles Les charges de 240Volts mises sous tension gr ce cette prise de doivent pas exc der 29 2 Amp res de courant Prise Verrouillage de 120 Volts...

Страница 28: ...u g n rateur se stabiliser le moteur tourne r guli rement et les dispositifs branch s fonctionnent correctement 4 Branchez et mettez la charge suivante en marche 5 De nouveau laissez le g n rateur se...

Страница 29: ...onnement propre et sec o celui l ne sera pas expos trop de poussi re de salet d humidit ou des vapeurs corrosives Les fentes de refroidissement par air du g n rateur ne doivent pas tre bouch es par de...

Страница 30: ...ture sur l unit Remisage du Moteur Voir les instructions sur la mani re de remiser correctement le moteur dans le manuel de l utilisateur du moteur Autres Id es de Remisage Pour viter la formation de...

Страница 31: ...31 7000EXL G n rateur Qui Dure Longtemps REMARQUES...

Страница 32: ...a de l eau dans l essence 9 Trop de starter 10 M lange de carburant trop riche 11 Soupape d admission bloqu e en position ouverte ou ferm e 12 Le moteur a perdu de sa compression 13 Batterie d fectue...

Страница 33: ...33 7000EXL G n rateur Qui Dure Longtemps REMARQUES...

Страница 34: ...7000EXL G n rateur Qui Dure Longtemps 34 REMARQUES...

Страница 35: ...ration un usage mauvais escient des n gligences un accident une surcharge une vitesse excessive un entretien inappropri une r paration ou un entreposage qui seront jug s par Generac Portable Products...

Страница 36: ...en subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in Generac Portable Products judgme...