46
LDS4 Colour Display System
© 2009 General Engine Management Systems Ltd.
LDS4 Colour Display System
·
Change defines the amount the stop watch trigger must change by before the stopwatch is
started. If set to zero, the stopwatch will start immediately the value changes. Higher values
can be used to ignore any noise in the stopwatch trigger input.
·
Calibration Factor defines the initial value of the distance calibration factor. All co-driver
distances are multiplied by the calibration before being displayed.
·
Countdown Trip defines the initial and reset values of the countdown trip.
·
Interval Trip Resolution and Total Trip Resolution define the display resolution of these
trip meters.
·
Fuel Countdown Init and Fuel Countdown Resolution define the initial value and
resolution of the fuel countdown trips.
9.2
Special Co-Driver Outputs
When co-driver support is enabled, some co-driver specific outputs are automatically added to
the setup. These outputs behave like any other and can be used with any gauge or in another
output.
There are three trip meters: a fuel meter, a stopwatch and the time defined as co-driver
outputs. For each of these master outputs a corresponding lap output is defined that holds the
same value as the master output. Each lap output has two actions available; start and stop:
·
The stop action freezes or laps the output, halting it at its current value.
·
The start action unfreezes the output which reverts to the corresponding master output
value.
All lap outputs are initially unfrozen. Note that changing the calibration factor while a lap output is
stopped does affect the frozen value.
For example, at the start of a stage, the Total Trip and Total Trip Lap outputs are both zero
and Total Trip Lap is unfrozen. The car launches off the line and both outputs increase
accordingly. A kilometre into the stage, the Total Trip Lap is frozen. The Total Trip continues
increasing and the Total Trip Lap shows its frozen value, say 0.95 kilometres. The Calib Factor
is adjusted and both the Total Trip and Total Trip Lap change appropriately. The Calib Factor
is changed such that the Total Trip Lap reads 1.00 kilometres. The Total Trip Lap is unfrozen
and now shows the same value as Total Trip.
The following list shows all the co-driver outputs that are added:
·
Calib Factor - The distance used by the trip meters is the distance input multiplied by the
Calib Factor. This allows fine calibration of the distance.
·
CountDown Trip - A trip meter that counts down from a preset value to zero.
·
CountDown Lap - The lap output of CountDownTrip.
·
Fuel Total - The total fuel used since the last fuel reset.
·
Fuel Total Lap - The lap output of Fuel Total.
·
Fuel Interval - The fuel used since the last interval reset.
·
Fuel Interval Lap - The lap output of Fuel Interval.
·
Total Trip - Total distance travelled since the trip meter was reset.
·
Total Trip Lap - The lap output of the Total Trip.
·
Interval Trip - Distance travelled since the last interval reset.
·
Interval Trip Lap - The lap output of Interval Trip.
·
Time - Current time of day.
·
Time Lap - The lap output of time.
·
Stopwatch - A stop watch with an accuracy of 0.005s.
·
Stopwatch Lap - The lap output of the Stopwatch.
Содержание LDS4