CHANGES FROM PREVIOUS EDITION
The following changes have been made to this manual (WI994C) since the previous edition (WI994B).
•
Page 2, "Important Notice", deleted NOTE which begins, "Typically, most versions of the GEM-P816 control panel can be upgraded…" and
ends, "...affixed to the GEM-P816 circuit board."
•
Page 6 contained a note with an asterisk, " *Not Evaluated by UL", referencing the Residential Burglary and Commercial Burglary specifica-
tions. This note was changed to "Commercial Burglary Specifications have not been Evaluated by UL".
•
Page 7, the
M278
Line-Reversal Module and the
Veri-Phone
Two-Way Module accessories now reference an asterisk (*) in that they have not
yet been evaluated by UL.
•
Page 7, references to UL609, UL1610, and UL365 listings were removed. (the GEM-P816/1632 panels have not yet been evaluated to these
standards). However, the listing of the Security Industry Association (SIA) False Alarm Reduction Standard CP-01 was added.
•
Page 8 specified that the system be serviced once every three years; this time period specification was changed to "annually".
•
All systems on Page 11 in WI808E have not been evaluated by UL and therefore were removed.
•
Page 13 in the Siren/Bell Power section, the following statement was added: "In NFPA Household Fire Installations, only a single siren or bell
can be used on this bell circuit."
•
Page 33 listed the "Easy Exit Always Enabled in Interior Mode" definition. This definition was changed as follows: The entry name was
changed to "Easy Exit"; the statement "Not Evaluated by UL" was added; the sentence, "Disable
D
or
U
buttons to initiate Silent (Easy) Exit."
was added.
•
The glossary definition on Page 34, "Exit Urgency Annunciation" was modified as follows: The following sentence was removed, "When armed
Stay, Silent Exit is evoked and time is doubled (120 seconds by default)".
•
The glossary definition on Page 37, "No EOL Resistor" now includes the following notation: "Note: Do not program for UL installations".
•
The glossary definition listed on Page 37, "Panic Zone…" was changed as follows: The entry name is now listed as "Panics"; the following sen-
tence was added: "Tamper must be enabled on the keypad".
•
The glossary definition on pages 39-40, "Swinger Shutdown" was modified.
•
See the chart on Page 52, The entry for "Cross Zoning", the following sentence was added: "The Cross Zone set time = one (1) minute".
•
All references to "Auto Reset after Alarm Time-Out" changed to "Auto Reset after Burglary Output Timeout".
•
All references to 0720-Bit 6--"Enable PGM2 Chirp on Keyfob Arming" name changed to "Chirp Output on Keyfob Arm/Disarm".
•
All references to 0722-Bit 0--"Automatic Interior Bypass" name changed to "Automatic Interior Bypass/Easy Exit".
•
All references to 0721-Bit 7--"Enable Bell Output on Keyfob Arming" name changed to "Select Alarm Output for Keyfob Chirp".
THIS MANUAL INCLUDES FEATURES WHICH ARE ONLY AVAILABLE IN CONTROL PANEL
FIRMWARE VERSION 10.0 OR LATER.
Refer to accompanying GEM-P816 Programming Instructions (WI995 and WI1182) for programming information.
IMPORTANT NOTICE
!
GEM-P816 panel version 10 requires the use of the following version keypads:
•
GEM-RP1CAe2 Version 8, GEM-K1CA Version 8
•
GEM-RP2ASe2, Version 6, GEM-K2AS, Version 6
•
GEM-RP3DGTL, Version 2, GEM-K3DGTL, Version 2
Upon entering program mode, the keypad display will flash the control panel firmware version, followed by the keypad firmware
version:
GEM-RP1CAe2: [1008], GEM-RP2ASe2: [1006], GEM-RP3DGTL: [1002]