background image

PAG 1

E 2

8.5 - PASSIVE ARMING

8.8 - CDL DOUBLE PULSE UNLOCK

9.0 - ULTRASONIC VOLUMETRIC SENSOR ADJUSTMENT

Engine block passive arming, if enabled, automatically activates the double
ENGINE LOCK 60 sec. after the engine has been switched OFF or 60 sec.
after the alarm has been disabled (if engine is not switched back on).
The status LED will flash quickly to confirm activation.

This function, if enabled, provides a double pulse unlock (approx. 0,5 seconds
each) upon disarming the system.
With the two-stage unlock, the first pulse unlocks the driver door and the
second pulse the remaining doors.
This function is only active if the lock/unlock time is set at 0,5”. Setting 6” will
automatically disable double pulse unlock.

The volumetric sensor provides interior protection. To adjust the sensitivity
level according to the area to the area that needs to be covered proceed as
follows:
- Arm the system excluding the sensors (see relative paragraph).
- Adjust the trimmer at a medium setting.
- After the arming delay, introduce an object in the cabin through the window
and move it around; the status LED will turn ON to signal a presence.
- If sensitivity level is too high or low, readjust the trimmer and repeat the above
procedure.

If a door is opened during the passive arming countdown, the countdown will
stop and start over again when the door is closed. The LED will be ON steady.

The comfort control feature automatically closes all windows when the alarm is armed.
If this function is enabled, the power window motor will receive a 25” command
to roll-up all windows when the alarm is armed.

8.6 - LOCK TIME

8.7 - COMFORT CONTROL

The lock time is factory preset at 0,5 seconds but it can be adjusted to 6
seconds during the programming phase.

If the comfort function has been enabled, keep the lock time set to 0,5”.

Setting it at 6” will cause the windows to open when the alarm is disarmed.

Содержание 7590TK15

Страница 1: ...AC2594 Rev 02 06 14 INSTALLATION AND USE MANUAL Made in Italy 7590TK15...

Страница 2: ...ELECTRICAL CONNECTIONS WIRING DIAGRAM PROGRAMMING THE ALARM SYSTEM PROGRAMMABLE FUNCTIONS 8 3 Current absorption sensor 8 4 Anti distraction rearming and auto lock 8 5 Passive arming 8 6 Lock time 8 7...

Страница 3: ...rtheuser This sign highlights useful information PAGE 3 2 0 FUNCTIONS Arming disarming via random rolling code transmitters Electrical engine immobilizer by passive arming Double engine immobilizer Bl...

Страница 4: ...s Different type batteries can seriously damage the remote control unit Discard used batteries properly in special dedicated containers he batteries are low the LED will start blinking when a button i...

Страница 5: ...em without any siren sound in case of an alarm event To exclude the siren Turn ignition key ON The LED will turn ON for approx 0 5 sec While the LED is ON press remote control button 2 The LED will tu...

Страница 6: ...will turn ON steady An alarm event can generate up to 5 alarm cycles for each input and for each arming cycle that will last 30 seconds each Ignition attempts and wire tamper alarms have no limitatio...

Страница 7: ...be signaled by 5 flashes of the turn indicators 5 8 PAGE 7 4 9 ALARM MEMORY Five flashes of the turn indicators when iginition is turned ON will indicate an alarm event has ocurred while you were awa...

Страница 8: ...rams for each specific vehicle can be requested to the zone dealer NB The BLACK 2 pin connectors in the alarm harness are for the electronic key and LED connections Negative Positive Engine immobiliza...

Страница 9: ...h GREEN BROWN GREEN BROWN Door switches See lock diagrams Engine immobilisation 1 Engine immobilisation 2 8A MAX 8A MAX Positive to alarm activated 700mA max GREEN GREEN BLACK marked R BLACK marked M...

Страница 10: ...ble a function press smooth button 2 LED will flash twice To modify settings proceed as follows Continuous siren or intermittent horn Double pulse unlock CDL 0 5 or 6 sec 25 comfort closure Current ab...

Страница 11: ...ity mode before the end of the 60 delay The LED will immediately turn OFF During the arming delay button 2 cannot be used to release the boot because it is used to exclude volumetric sensors and comfo...

Страница 12: ...needs to be covered proceed as follows Arm the system excluding the sensors see relative paragraph Adjust the trimmer at a medium setting After the arming delay introduce an object in the cabin throu...

Страница 13: ...n an already learned remote or insert an already learned electronic key in its receptacle Two slow flashes of the turn indicators will confirm the system has entered in learn mode According to the dev...

Страница 14: ...date shown on this warranty in compliance with Directive 1999 44 CE Please fill in entirely the guarantee certificate included in this booklet and DO NOTREMOVE the guarantee label from the device The...

Страница 15: ...GIES S p A GEMINI 7208E and 7218E We the undersigned R TTE Declaration of Conformity Doc ref No 2010 01 Declare under our sole responsibility that the following equipment Is tested to and conforms wit...

Страница 16: ...7 Dudley Court Jessop Close Clacton on Sea Essex CO15 4LY TEL 44 0 1255 434353 Email sales avsgemini com Web www avsgemini com UK Distributors of the Gemini Alarm Systems...

Отзывы: