V
02/16
24
•
Operation
OptiMove CR08
The OptiMove control unit is switched on.
The blinking LED of the key
indicates that reference point travel
has not been carried out yet.
2. Press
the key
The control unit starts the reference travel
3.
At the end of the reference travel, the LED of the
key expires
and the axis is referenced
NOTE
If the axis can collide somewhere, or the guns are incorrectly mounted,
or the lower reversing point is situated too low, the axis can be
stopped by pressing the
key. By pressing the key again, the
reference travel will continue.
The procedure described above relates to the reference point traveling in
manual operation.
Start/stop the axis
1.
Switch on the axis control unit (see also "Switch on/off the axis
control unit")
2.
If necessary, change to another program (see also "Program
change")
3. Press
the key.
The axis is started, and the selected program is activated. The
corresponding LED illuminates
4. Press
the key.
Axis is stopped
– The
display
A1
shows the actual axis position. The
corresponding LED remains unlit
Program change
The program change can be done via keyboard (manually). In addition, a
program change can be made either during operation or at a standstill. In
both cases the modifications are stored in the program memory, i.e. after
restarting the OptiMove control unit, the last entered axis programs are
available again.
NOTE
If a program change is made during operation, the axis terminates the
old command, which is still in the memory, and takes over the new
program (positions or speed) by the next cycle change!
1.
Select the desired program number using
keys