Fault clearance
OptiFlex 2 F
Code
Description
Criteria
Remedy
Pneumatics:
H05
PowerClean valve
– PowerClean valve not
connected
– Valve defective
– Connection cable
defective
– Mainboard defective
connect or replace
Contact a Gema service
center
H06
Trigger valve
Solenoid coil current lower than
preset limiting value
Valve defective, main board or
cable defective
Contact a Gema service
center
H07
Supplementary air
volume too high
(setting of supplementary
air on the display)
The preset value for
supplementary air is too high
compared to the conveying air
setting
Lower supplementary air
value or increase value for
conveying air to equalize
air volumes to the injector,
delete error code
H08
Conveying air volume too
high (setting of powder
share on the display)
The preset value for conveying
air is too high compared to the
supplementary air setting
Lower conveying air value
or increase value for
supplementary air to
equalize air volumes to the
injector, delete error code
H09
Powder output higher
than 100%
The powder output multiplied by
the powder hose length factor
and daily correction value is
greater than 100%
Daily correction value too large
Reduce powder output
Reduce daily correction
value
H10
Conveying air range
lower deviation
The theoretical value for convey-
ing air falls below minimum
Total air is smaller than minimum
Limit conveying air to its
minimum value
High voltage:
H11
Gun error
No vibrations in the oscillator,
cable break, oscillator or gun is
defective
Contact a Gema service
center
H13
Intermediate circuit
voltage too high
Mainboard defective, device is
switched off
Contact a Gema service
center
H14
Offset spray current
measurement
Grounded current measurement
Contact a Gema service
center
Power supply:
H21
Supply undervoltage
Power pack defective or
overloaded
Contact a Gema service
center
EEPROM (equipment memory):
H24
EEPROM content invalid
EEPROM error
Contact a Gema service
center
H25
Timeout during EEPROM
writing
EEPROM error
Contact a Gema service
center
H26
Values not correctly
stored in EEPROM during
switching off
EEPROM error
Contact a Gema service
center
Содержание OptiFlex 2 F
Страница 12: ...Rev 00 09 16 12 Safety OptiFlex 2 F ...
Страница 20: ...Rev 00 09 16 20 Assembly Connection OptiFlex 2 F ...
Страница 32: ...Rev 00 09 16 32 Operation OptiFlex 2 F 29 30 ...
Страница 34: ...Rev 00 09 16 34 Decommissioning Storage OptiFlex 2 F ...
Страница 48: ...Rev 00 09 16 48 Fault clearance OptiFlex 2 F ...
Страница 52: ...Rev 00 09 16 52 OptiSelect GM03 OptiFlex 2 F ...
Страница 59: ...Rev 00 09 16 OptiFlex 2 F Maintenance Repairs 59 Replacing the insert sleeve 1 2 3 4 ...
Страница 60: ...Rev 00 09 16 60 Maintenance Repairs OptiFlex 2 F ...
Страница 62: ...Rev 00 09 16 62 Fault clearance OptiFlex 2 F ...
Страница 65: ...Rev 00 09 16 OptiFlex 2 F Spare parts list 65 OptiFlex 2 F Spare parts fig 14 ...
Страница 75: ...Rev 00 09 16 OptiFlex 2 F Spare parts list 75 SuperCorona 1 SuperCorona PC05 1008 165 Wearing part Fig 23 ...
Страница 82: ...Rev 00 09 16 82 Spare parts list OptiFlex 2 F OptiFlow IG06 spare parts fig 24 ...
Страница 84: ...Rev 00 ...