Rev. 00 09/16
24
Operation
OptiFlex 2 F
of the powder hopper; otherwise the fluidized powder can
escape from the cover.
– Close the filling cover of the powder hopper again.
4.
Set coating parameters:
1.
Turn on the gun control unit with the
ON
key
2.
Press the corresponding application key.
The arrow above the desired button lights up.
The pre-defined application modes have preset values for high
voltage and spray current:
Application mode
Preset µA
Preset kV
flat parts
100
100
complicated parts
22
100
overcoat
10
100
3.
The air values for total air, powder output and electrode rinsing air
can be individually defined and are saved in the programs.
Starting the user-defined operating mode
(Program mode)
1.
Turn on the gun control unit with the
ON
key
2.
Press the
program key
3.
Select desired program (01-20)
Program 20 active
4.
Change coating parameters as required
Programs 01-20 are preset at the factory but can be modified at
any time, after which they are automatically stored.
Содержание OptiFlex 2 F
Страница 12: ...Rev 00 09 16 12 Safety OptiFlex 2 F ...
Страница 20: ...Rev 00 09 16 20 Assembly Connection OptiFlex 2 F ...
Страница 32: ...Rev 00 09 16 32 Operation OptiFlex 2 F 29 30 ...
Страница 34: ...Rev 00 09 16 34 Decommissioning Storage OptiFlex 2 F ...
Страница 48: ...Rev 00 09 16 48 Fault clearance OptiFlex 2 F ...
Страница 52: ...Rev 00 09 16 52 OptiSelect GM03 OptiFlex 2 F ...
Страница 59: ...Rev 00 09 16 OptiFlex 2 F Maintenance Repairs 59 Replacing the insert sleeve 1 2 3 4 ...
Страница 60: ...Rev 00 09 16 60 Maintenance Repairs OptiFlex 2 F ...
Страница 62: ...Rev 00 09 16 62 Fault clearance OptiFlex 2 F ...
Страница 65: ...Rev 00 09 16 OptiFlex 2 F Spare parts list 65 OptiFlex 2 F Spare parts fig 14 ...
Страница 75: ...Rev 00 09 16 OptiFlex 2 F Spare parts list 75 SuperCorona 1 SuperCorona PC05 1008 165 Wearing part Fig 23 ...
Страница 82: ...Rev 00 09 16 82 Spare parts list OptiFlex 2 F OptiFlow IG06 spare parts fig 24 ...
Страница 84: ...Rev 00 ...