Fault clearance
OptiFeed BigBag (FPS16)
Code
Description
Criteria
Remedy
H42
Overflow on data
reception
The message to be received has
no more place in the receiver
buffer. Messages are sent faster
than they can be processed.
Contact Gema Service
H43
Overflow on transmission
The message to be sent has no
more place in the transmission
buffer. Messages are produced
faster than they can be sent.
Contact Gema Service
H44
Master failed
Node Guarding message is
missing longer than 2 seconds.
Connection to master failed.
Check the connection to
the Master, otherwise
contact Gema service
H45
Parameter value outside
the value range
The sent parameter value is
outside the allowed value range
Check input values
H46
Invalid Node ID set
The Node ID is not between 1
and 127
Set Node ID to 127
H47
No CAN interface
installed
CAN interface is selected in the
system parameters, but no
interface is installed
Contact Gema Service
H48
No ACK to “Boot Up
Message” received
No CAN node is answering to
the “Boot Up Message”
Check cabling connections
between the users,
otherwise contact Gema
service
Display module:
H50
Firmware update for
display required
The firmware installed on the
display is not supported
Replace or update display
Throttle motors:
H60
Transport air reference
position not found
Throttle motor or needle
jammed, limit switch defective,
error in motor throttle
Contact Gema Service
H61
Vacuum reference
position not found
Throttle motor or needle
jammed, limit switch defective,
error in motor throttle
Contact Gema Service
H64
Transport air throttle does
not move
Short circuit in limit switch, motor
throttle defective
Contact Gema Service
H65
Vacuum throttle does not
move
Short circuit in limit switch, motor
throttle defective
Contact Gema Service
H68
Transport air throttle
position lost
Lost steps, limit switch defective,
throttle motor defective
Contact Gema Service
H69
Vacuum throttle position
lost
Lost steps, limit switch defective,
throttle motor defective
Contact Gema Service
Pneumatics:
H80
Pressure regulator
transport air
Actual transport air pressure out
of tolerance
Check compressed air
supply (insufficient air
volume flow)
Contact Gema Service
H81
Pressure regulator
vacuum
Vacuum value out of tolerance
Contact Gema Service
H82
Pressure regulator PV air
supply
Actual pressure PV supply out of
tolerance
Contact Gema Service
Содержание FPS16
Страница 6: ......
Страница 34: ...Rev 00 03 22 34 Start up OptiFeed BigBag FPS16 ...
Страница 38: ...Rev 00 03 22 38 Operation OptiFeed BigBag FPS16 ...
Страница 52: ...Rev 00 03 22 52 Fault clearance OptiFeed BigBag FPS16 ...
Страница 54: ...Rev 00 03 22 54 Disposal OptiFeed BigBag FPS16 ...
Страница 60: ......
Страница 62: ...Rev 00 ...