GEMÜ 649 eSyDrive
19 Inspection and maintenance
19.1 Spare parts
A
1
18
19
20
2
Fig. 13: Spare parts
Item
Name
Order description
A
Actuator
9649
1
Valve body
K600
2
Diaphragm
600…M
18
Bolt
649…S30…
19
Washer
20
Nut
19.2 Removing the actuator
1. Move the actuator
A
to the open position.
2. Loosen the fastening elements between actuator
A
and
body
1
diagonally and remove them.
3. Lift actuator
A
off valve body
1
.
4. Move the actuator
A
to the closed position.
5. Clean all parts of contamination (do not damage parts dur-
ing cleaning).
6. Check parts for potential damage, replace if necessary
(only use genuine parts from GEMÜ).
19.3 Removing the diaphragm
1. Remove actuator
A
(see chapter "Removing the actuator").
2. Unscrew the diaphragm.
ð
Please note: Depending on the version, the com-
pressor may fall out.
3. Clean all parts of contamination (do not damage parts dur-
ing cleaning).
4. Check parts for potential damage, replace if necessary
(only use genuine parts from GEMÜ).
19.4 Mounting the compressor
D
D
C
C
1. Place the compressor loosely on the actuator spindle.
2. Fit recesses
D
into guides
C
.
ð
The compressor must be able to be moved freely between
the guides.
19.5 Mounting the diaphragm
19.5.1 Mounting the convex diaphragm
NOTICE
▶
Fit the diaphragms suitable for the product (suitable for
medium, medium concentration, temperature and pres-
sure). The diaphragm is a wearing part. Check the tech-
nical condition and function of the product before com-
missioning and during the whole term of use. Carry out
checks regularly and determine the check intervals in ac-
cordance with the conditions of use and/or the regulatory
codes and provisions applicable for this application.
NOTICE
▶
If the diaphragm is not screwed into the adapter far
enough, the closing force is transmitted directly onto the
diaphragm pin and not via the compressor. This will
cause damage and early failure of the diaphragm and
leakage of the product. If the diaphragm is screwed in too
far, perfect sealing at the valve seat will not be achieved.
The function of the product is no longer ensured.
NOTICE
▶
Incorrectly mounted diaphragms cause the product leak-
age and emission of medium. In this case, remove the
diaphragms, check the complete valve and diaphragms
and reassemble again proceeding as described above.
Содержание 649 eSyDrive
Страница 24: ...9 2 5 www gemu group com 24 48 GEM 649 eSyDrive 9 Dimensions...
Страница 26: ...9 2 7 www gemu group com 26 48 GEM 649 eSyDrive 9 Dimensions...
Страница 30: ...10 www gemu group com 30 48 GEM 649 eSyDrive 10...
Страница 37: ...www gemu group com 37 48 GEM 649 eSyDrive 15 6 15 Electrical connection...