10.1.1 Single mounting - GEMÜ 0322
P
A
3
7
1
4
2
5
Fig. 1: Single mounting - GEMÜ 0322
1. Fasten the pilot solenoid valve with two machine screws
1
(ø 2.5 mm). Max. screw depth: 10 mm.
2. Connect and seal the pressure inlet tubing to connection
"P" 2 (G 1/4).
Only use screwed plugs form A or B, short
design, to DIN 3852!
3. If applicable, connect and seal the exhaust tubing to con-
nection "R"
5
(M5) or mount a silencer.
4. Connect and seal the outlet tubing to connection "A"
4
(G
1/4).
5. Close the open connection "P" with supplied sealing plug
3
and O-ring
7
.
6. All threads must be sealed gas tight.
10.1.2 Battery mounting - GEMÜ 0322
P
A
P
A
3
7
7
2
5
4
1
6
Fig. 2: Battery mounting - GEMÜ 0322
1. Insert O-ring
7
into base recess.
2. Press the pilot solenoid valves together and insert brack-
ets
6
into the respective retainers from below.
3. The brackets
6
hold the pilot solenoid valves together and
also serve as fastening elements.
4. Fasten the pilot solenoid valve battery with screws
1
.
5. Connect and seal the pressure inlet tubing to connec-
tion"P"
2
(G 1/4).
Only use screwed plugs form A or B,
short design, to DIN 3852!
6. If applicable, connect and seal the exhaust tubing to con-
nection "R"
5
(M5) or mount a silencer.
7. Connect and seal the outlet tubing to connection "A"
4
(G
1/4).
8. Close the open connection "P" with supplied sealing plug
3
and O-ring
7
.
9. All threads must be sealed gas tight.
After the installation:
–
Re-attach or reactivate all safety and protective
devices.
10 Installation