7
www.geiger.de
EN
EN
9. Starting the setting modes
PROG key
pressed in sec.
Mode
Reaction
Options
Feedback
Learning
mode
activated
Start-Stop-
Start by
each run.
Move in UP direction for
referencing ON
1 x Stop & Go
Move in DOWN direction for
referencing OFF
2 x Stop & Go
Any move in
UP and DOWN direction
is possible.
1 x UP-DOWN 3 x UP-DOWN
4 x UP-DOWN
Referencing
activated
Reset
to factory setting
0
3
6
20
30
As soon as the drive has entered the respective mode and has started to respond, the PROG
key can be released and the appropriate setting can be made.
10. Factory settings
The drive is delivered with the factory settings which allow any number of UP and DOWN runs
with max. power.
This mode is optimally suited for initial commissioning in the factory.
11. Automatic setting of the end positions
I
The distance between the upper and lower end stops must be about
7 cm which corresponds to 1/4 tube rotation at least. If the distance is
not maintained the drive deletes the end positions that have already
been stored and starts again with the programming.
Programming the end positions
1.
To activate the programming mode, press the PROG key or the UP and DOWN keys at the
same time until the motor confirms (1 x „clac-clac“). The learning mode is indicated with
each move command by a short interruption of the screen movement (start-stop-start).
2.
Keep the UP or DOWN key pressed to move the screen to the desired end position until the
motor reaches the stop and switches off (torque shutoff).
3.
Keep the UP or DOWN key presses to move the screen in the opposite direction until the
motor reaches the stop and switches off (torque shutoff).
4.
The programming process is then completed and the motor switches to normal operation.
I
The direction of rotation of the motor is automatically assigned to the
upper and lower end positions.
I
The end positions are stored only after the second torque switch-off
for each end position.