17. Referencing / End position correction
If, e.g. due to temperature changes, a
screen elongation/shortening
has occurred, this is
automatically corrected when the screen is closed, depending on the setting.
If, due to changes in temperature, the
winding behaviour
should change and the screen should
run against the stop, an immediate end position correction or a torque shut-off takes place,
depending on the setting.
After the first reference run, the motor automatically detects the torque required to close the
screen and closes it with the lowest possible force in order to optimally protect the fabric.
18. Resetting to factory setting
To reset the drive to the factory setting, press the PROG key for 20 to 30 sec. The drive signals
the reset with 4 UP/DOWN movements.
The drive returns to the delivery state.
19. What to do if…
Problem
Solution
Motor does not run.
•
Motor not plugged in.
Please check the plug connection.
•
Check connecting cable for possible
damage.
•
Check the mains voltage and allow the
cause of the voltage break down to be
tested by a specialist
electrician.
Instead of in the upwards direction, motor
runs downwards.
•
The control leads are interchanged.
Exchange black/brown control leads.
Motor only runs in one
direction.
•
Motor in the end position.
Run motor in the opposite direction.
Re-adjust the end positions, if necessary.
After running several times,
the motor breaks down and
no longer responds.
•
The motor became too hot and has
switched off.
Try it again after a cooling time of about
15 min.
20. Maintenance
The drive is maintenance-free.