GEIGER SOLIDline ZIP-Perfection GU45 E11 Series Скачать руководство пользователя страница 5

5

www.geiger.de

EN

EN

6.  Installation instructions

 

I

Before fixing, the strength of the masonry or of the subsurface is to be 

checked.

 

I

Prior to installation please check to ensure there is no visible damage 

to the motor like cracks or open cables.

 

I

Caution: If the tube is screwed/riveted to the drive, the measure must 

be taken from the tube end to the center of the drive and marked on 

the tube.

When drilling the winding shaft 

never

 drill into the  

area of the tubular motor!
When inserting into the shaft, the tubular motor must 

not

 

be struck and must 

not

 be allowed to fall into the shaft.

Installation into the screen:

Insert motor with a suitable adapter and drive into the shaft 

up to the stop of the shaft adapter.
Fix the motor support on the side piece. 
Fix the motor together with the shaft on the motor support. 

Depending on the selected motor head, 

different fixation systems can be used:

 

– Place the motor with square insert in the star-shaped 

bearer and lock with pin

 

– Place the motor into the existing engine bearer and 

lock

 

– Place the motor in a compatible engine bearer with clip 

system and lock with spring or rotating lever

 

I

The GEIGER SOLIDline motor is suitable 

for shaft diameters from 50 mm!

Содержание SOLIDline ZIP-Perfection GU45 E11 Series

Страница 1: ...ing instructions Notice originale de montage et d utilisation Instrucciones originales de instalación y funcionamiento Istruzioni originali di installazione e funzionamento EN FR ES IT Tubular motor GEIGER SOLIDline Motor control SOLIDline ZIP Perfection GU45 E11 for screens with ZIP guidance ...

Страница 2: ...ion contrary to the installation and operating instructions and or constructional modification the legal and contractual guarantee for property damage and product liability lapses Index 1 General information 2 2 Guarantee 2 3 Intended use 3 4 Safety instructions 3 5 Safety instructions for assembly 4 6 Installation instructions 5 7 Information for the specialist electrician 6 8 Connection of the s...

Страница 3: ... tions such as for example window cleaning are being carried out in the vicinity f f During operation observe the danger zone f f Do not use the installation if people or objects are in the danger zone f f Urgently shut down damaged installations until repair f f Unconditionally shut down the unit during maintenance and cleaning operations f f Pinching and shearing points are to be avoided and mus...

Страница 4: ...d any other fixed element f f The rated speed and the rated torque of the motor must be compatible with the device f f The mounting accessories that are used must be designed in accordance with the selected rated torque f f Good technical knowledge and good mechanical skills are necessary for the motor installation Incorrect installation can lead to serious injury Electrical work must be carried o...

Страница 5: ... shaft the tubular motor must not be struck and must not be allowed to fall into the shaft Installation into the screen Insert motor with a suitable adapter and drive into the shaft up to the stop of the shaft adapter Fix the motor support on the side piece Fix the motor together with the shaft on the motor support Depending on the selected motor head different fixation systems can be used Place t...

Страница 6: ... connectors of the Hirschmann Company are tested and approved with couplings of the Hirschmann Company In order to prevent a malfunction caused by coupling the supply line ref NYM from the actuator switch to the motor must not exceed 100 m in case of motors with electronic end stops 8 Connection of the setting switch I I In order to set the end positions on SOLIDline motors any setting switch can ...

Страница 7: ...e about 7 cm which corresponds to 1 4 tube rotation at least If the distance is not maintained the drive deletes the end positions that have already been stored and starts again with the programming Programming the end positions 1 To activate the programming mode press the PROG key or the UP and DOWN keys at the same time until the motor confirms 1 x clac clac The learning mode is indicated with e...

Страница 8: ...mi automatic programming of the end positions I I The distance between the upper and lower end stops must be about 7 cm which corresponds to 1 4 tube rotation at least If the distance is not maintained the drive deletes the end positions that have already been stored and starts again with the programming Programming the end positions 1 To activate the programming mode press the PROG key or the UP ...

Страница 9: ...acle is still detected the drive returns to the corresponding end position I I Because of the motor sensitive obstacle detection the correct dimen sioning of the torque for the respective installation size is essential Note the chart below serves only as indication to determine the motor size Whether the specified motor size is sufficient for the respective installation size and is sensitive enoug...

Страница 10: ...e drive to the factory setting press the PROG key for 20 to 30 sec The drive signals the reset with 4 UP DOWN movements The drive returns to the delivery state 19 What to do if Problem Solution Motor does not run Motor not plugged in Please check the plug connection Check connecting cable for possible damage Check the mains voltage and allow the cause of the voltage break down to be tested by a sp...

Страница 11: ...6 GS56 GS45 GB45 GB35 Applied directives 2006 42 EG 2014 53 EU 2011 65 EU EU 2015 863 EU 2017 2102 Applied standards EN 60335 1 2012 EN 60335 1 2012 AC 2014 EN 60335 1 2012 A11 2014 EN 60335 1 2012 A13 2017 EN 60335 1 2012 A1 2019 EN 60335 1 2012 A14 2019 EN 60335 1 2012 A2 2019 EN 60335 2 97 2006 A11 2008 A2 2010 A12 2015 EN 62233 2008 EN 62233 Ber 1 2008 EN 55014 1 2017 EN 55014 2 2015 EN 61000 ...

Страница 12: ... 45 mm Weight ca 1 85 kg ca 1 90 kg ca 2 20 kg ca 2 40 kg Storage temperature Humidity T 15 C 70 C dry and non condensing place 1 SOLIDline ROC 5 9 mm SOLIDline COM 4 2 mm 2 The average sound pressure level data are intended for guidance only The values were determined by GEIGER at a distance of 1 m with a hanging motor at idle speed and averaged over 10 seconds There is no reference to any specif...

Отзывы: