10.4.3
Control unit on the roof of the car
1 =
EMERGENCY STOP
2 = Triggers a lubricating pulse
LEFT = increased lubricating
impulse
MIDDLE = normal lubricating
impulse
RIGHT = manually activating
lubricating impulse*)
3 = EMERGENCY lighting
4 = SCHUKO
®
socket
230 V / 6 A
5 = Connector
Dummy plug in normal mode /
assembly control / drop test
control
Example
Assembly mode / Assembly control is plugged and hold the button
10 seconds in this position
-> 20 minutes permanent lubrication.
Assembly mode / Assembly control is plugged:
-> The lubrication facility automatically lubricates with increased
impulse while driving.
10.4.4
Assembly crane control unit
This control unit is permanently connected to
the boom truck.
1 =
EMERGENCY STOP
(for assembly crane)
only switches off the assembly crane.
2 = Rocker switch for
UP
and
DOWN
ATTENTION