10.3.6
Landing switch box
The car can be stopped at any time using the
EMERGENCY
-
STOP
button (1).
1 =
EMERGENCY STOP
button (does not engage)
3 =
UP
button
4 =
DOWN
button
5 =
S
top
N
ext
L
anding (SNL)
Stop at next landing level
The supply line (7) [7-pole plug, red] from the first landing level door switch
box is plugged into the ground station at the switch box.
If there are several levels with level controls, the supply line (7) [7-pole
plug, red] from the second level is plugged into the socket (6) on the
control of the level below.
The dummy plug is always changed over from the switch cabinet of
the ground station to the top landing call box.