Button "
S
top
N
ext
L
anding" illuminates. The car only moves slowly and
stops at the next landing below.
Stop at the actual position
Press the
STOP
button. The car stops at the current position
10.3.2
Control in the car - landing preselection
1 = actual landing display
Error code and
diagnostic display
2 = Car emergency lighting
3 =
EMERGENCY STOP
4 = Key field
0-9 = Landing level
selection
# = Start button
* = No function
5 =
S
top
N
ext
L
anding (SNL) Stop at next landing level
(only when landing approach bar is installed)
Illuminated when operated.
Press and hold
EMERGENCY DOWN
button.
after approx. 30 seconds, the car moves to the ground station.
6 =
Ready for operation control light
OFF = not ready for service (refer to error code on the diagnostic display)
ON = Ready for operation
7 =
Overload warning light
ON = Overload
Flashing once per second = Lubrication empty
Flashing twice per second = refer to error code on the diagnostic display
8 = Landing display of the travel destination
1
2
8
5
3
4
6 7
Содержание PH 650
Страница 1: ...Original operating manual Operating Manual Car PH 2032 PH 2737 PH 3240 Single Twin...
Страница 2: ......
Страница 3: ...GEDA Temporary Construction Hoist PH 650 Operating Manual Page 3 of 64 BL148GB2017 11...
Страница 4: ...GEDA Temporary Construction Hoist PH 650 Operating Manual Page 4 of 64 BL148GB2017 11...
Страница 8: ...GEDA Temporary Construction Hoist PH 650 Operating Manual Page 8 of 64 BL148GB2017 11...
Страница 63: ......