EN
42
B1157-002 © 01-2015
966.475.00.0 (01)
LED displays for
<Mains
connection>
,
<Ready for
welding>
and
<Welding
complete>
light up, and
<General
malfunction> LED
display
flashes
Sleeve connection
plugs worn or too
many interruptions
from removing the
sleeve connection
plugs during
welding procedure
`
Disconnect the mains
plug
`
Visually inspect the
sleeve connection plugs
and sleeve connection
cables if necessary, or
replace the connecting
cables
`
Send the electrofusion
machine to a qualified
service centre
1)
1) For addresses of qualified service centres, contact your Geberit sales
company or visit www.geberit.com
Fault
Cause
Actions