![Geberit ESG 3 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/geberit/esg-3/esg-3_operation-manual_4037680037.webp)
EN
37
B1157-002 © 01-2015
966.475.00.0 (01)
1
Connect the electrofusion machine to the supply voltage. The
<Mains connection> LED display lights up (see figure A,
rear cover page).
2
Connect the sleeve connection cable to the electrofusion
coupling or the electrofusion tape for anchor point. The
<Ready for welding> LED display lights up (see figure B,
rear cover page).
3
Press the start button. The <Welding procedure> LED
display lights up and the <Ready for welding> LED display
goes out (see figure C, rear cover page).
The Geberit electrofusion machine ESG 3 is equipped with
an automatic mechanism which prevents a double weld
when a sleeve connection cable is connected.
The welding time is adjusted automatically in accordance
with the ambient temperature.