POWER SUPPLY
During installation: Always disconnect system power supplies.
During installation and operation, the user (commissioning engineer) must comply with the regulations according to IEC 60950-1:
Protection against contact with parts of hazardous voltage and compliance with insulation requirements.
6.1
FIXED VOLTAGE POWER SUPPLY
The printer can be operated with a fixed voltage power
supply of 24 VDC ±10%.
Depending on the mounting position: horizontal or vertical,
the corresponding socket is used according to the chapter
3.2 CONNECTIONS, page 8.
The connected power supply has to be protected against
overvoltage in accordance with EN/IEC 60950. Suitable
power supplies for the printer is available from GeBE, see
chapter 4.3 ACCESSORIES AND SPARE PARTS, page 10.
It is recommended to select the cable length as short as
possible. Long cable lengths lead to high resistance that
results in a poor print image up to failure of the printer.
Connection horizontal J1 (GCT-4663-50)
Pin Function
1
GND
2
GND
3
VP
4
VP
Socket:
KLD-SMT2
J1
Mating connector: Coaxial power connector ø 5,5/2,1mm
Connection vertical J211 (GCT-4663-50)
Pin Function
1
VP
2
GND
3
GND
Socket:
KLDVX-0202
J211
Mating connector: Coaxial power connector ø 5,5/2,1mm
IMPORTANT: Only connection J1 or J211 may be used.
Suitable connection cable: please refer to chapter
4.3 ACCESSORIES AND SPARE PARTS, page 10.
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. GPT-4673-LL-Testbench-C32-E-SMAN-V1.0-0973
Feinwerktechnik GmbH
fax
+49.89.894141-33
date September 4, 2019
Beethovenstraße 15
page 23 | 34
82110 Germering
Our general terms of business are to be applied.