GeBE-TESTBENCH Linerless
GPT-4673
5.4.3 PROGRAMMING STOP AT PAPER END
The software GeBE-Toolbox defines how many tickets will
be printed after the NPE sensor has been triggered.
The right combination of NPE position and software
settings must be determined by testing.
The entry field for the stop condition is located in the
bottom right of the GeBE-Toolbox menu „Periodic Send“.
1.
Activate the stop function by setting the activation
hook (1).
2.
Press the button „Reset“ (2).
3.
Enter the desired number of tickets to be printed
after NPE activation, in the field (3). Here in the
example above: 4 tickets.
4.
Confirm the entry by pressing the "save new value"
button (4).
5.
Start the printing process (longruntest.xml).
A detailed description is available in our technical
information of GeBE-Toolbox INFO-Toolbox-DE-0819,
which can be requested at GeBE support via email
6.
In field (3) a countdown starts with each printed
ticket until 0 = stop.
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. GPT-4673-LL-Testbench-C32-E-SMAN-V1.0-0973
Feinwerktechnik GmbH
fax
+49.89.894141-33
date September 4, 2019
Beethovenstraße 15
page 22 | 34
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.
(1)
(3)
(4) (2)
(3)