GeBE-TESTBENCH Linerless
GPT-4673
5.4 TEST PROCEDURE WITH GeBE TOOLBOX
The GeBE Toolbox is supplied with several files:
Standard test retail tickets with different print width:
BON-tahoma-640x480.prn
BON-tahoma-448x480.prn
BON-tahoma-448x480L.prn
Grey print for silicone peeling off:
grey640.prn
Platen slip test:
Schlupftest.prn
Standard test printout:
testprint640.prn
testprint448.prn
testprint448L.prn
5.4.1 TEST PREPARATION
1. The printhead is clean.
2. The printhead temperature is 20°C – 25°C.
3. Do not use the first approx. 0.5 m of a new paper
roll.
Hint:
If there are any fluctuations in the print quality, first clean
the printhead and eliminate any possible causes of
contamination. Due to the nature of the process, silicone
deposits on the printhead coming from the paper can
occur during operation. These deposits increasingly occur:
1. with a cold printhead.
2. at very low print speed. This is especially the case
at printing start, where the print speed is nearly
zero at the first print lines.
3. if large areas has to be blackened.
4. if the quality varies within a paper roll.