GeBE-TESTBENCH Linerless
GPT-4673
7
INTERFACES
The controller GCT-4663 contains two USB full speed interfaces.
Avoid connecting cables when the power supply is switched on. If this is not possible, make sure that the USB interface is always
connected after the power supply has been plugged in.
Detailed controller information is available from the hardware description HaMAN-E-0813, which can be requested from GeBE via
email (
7.1
USB INTERFACE
The suitable interface cable has to be connected at
horizontal application to the socket (2/figure 2) or at
vertical application to the socket (3/figure 2). On the other
side directly to an USB connection (COM port of a PC).
Connection J2 or J212 (GCT-4663)
Pin
Function
Dir
1
USB-Power
-
2
USB D-
I/O
3
USB D+
I/O
4
GND
-
5
Frame GND
-
Socket:
USB-B
J2 / J212
Mating connector:
USB-B 90°
J2
USB-B 180°
J212
IMPORTANT: Only connection J2 or J212 may be used.
Suitable connection cable: please refer to chapter
4.3 ACCESSORIES AND SPARE PARTS, page 10.
The USB device class is consistent with the "Printer Class".
After the PC is plugged in, it reports "USB printer support"
and installs an "USB00x" USB port. During the installation
of the printer driver, it has to be allocated to the USB port.
USB specification
USB 2.0 FS
Device type
Printer Class
USB
Full Speed 12 Mbit/s
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. GPT-4673-LL-Testbench-C32-E-SMAN-V1.0-0973
Feinwerktechnik GmbH
fax
+49.89.894141-33
date September 4, 2019
Beethovenstraße 15
page 24 | 34
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.