English
within generator rated output. Be sure the receptacle
load current is within receptacle rated current.
TIP:
Make sure to ground (Earth) the generator. When the
electric device is earthed, always the generator must
be earthed.
TIP:
1. Start the engine.
2. Turn the ESC to “ON”.
3. Plug in to AC receptacle.
4. Make sure the AC pilot light is on.
5. Turn on any electrical device
TIP:
The ESC must be turned to “OFF” before increasing
engine speed to rated rpm.
• For connection and simultaneous use of multiple
items, always make sure the device that pulls the
most current at startup time starts first. Then start
equipment that pulls less power.
• Always make sure that the equipment that is
connected together does not pull more than that
the power supply produces.
BATTERY CHARGING
- The generator DC rated voltage is 12V.
- Start the engine first, and then connect the
generator to the battery for charging.
- Before starting to charge the battery, make sure
that the DC protector is turned on.
1. Start the engine.
2. Connect the red battery charger lead to the
positive (+) battery terminal.
3. Connect the black battery charger lead to the
negative (-) battery terminal.
4. Turn the ESC “OFF” to start battery charging.
• Be sure the ESC is turned off while charging the
battery.
• Be sure to connect the red battery charger lead to
the positive (+) battery terminal, and connect the
black lead to the negative (-) battery terminal. Do
not reverse these positions.
• Connect the battery charger leads to the
battery terminals securely so that they are not
disconnected due to engine vibration or other
disturbances.
• Charge the battery in the correct procedure by
following instructions in the owner’s manual for
the battery.
• The DC protector turns off automatically if current
above the rated flows during battery haring. To
restart charging the battery, turn he DC protector
on by pressing its button to “ON”. If the DC
protector turns off again, top charging
TIP:
• Follow instructions in the owner are manual for the
battery to determine the end of battery charging.
• Measure the specific gravity of electrolyte to
determine if the battery is fully charged. At full
charge, the electrolyte specific gravity is between
1.26 and 1.28.
• It is advisable to check the specific gravity of the
electrolyte at least once every hour to prevent
overcharging the battery.
When charging a car battery, do not start the car
engine while the charging cables are connected
and the power supply is running. This can cause
damage to both the car electrical system and power
supply.
Never smoke or make and break connections at
the battery while charging. Sparks may ignite the
battery gas. Battery electrolyte is poisonous and
dangerous, causing severe burns, etc. contains
sulfuric (sulphuric) acid. Avoid contact with skin,
eyes or clothing.
IMMEDIATE ACTIONS IF IN CONTACT WITH
BATTERY ACID:
External -
Flush with water.
Internal -
Drink large amount of water and contact hospital
immediately.
Eyes -
Flush with water for 15 minutes and get prompt
medical attention.
Batteries produce explosive gases. Keep sparks,
flame, cigarettes, etc., away. Ventilate when charging
or using in closed space. Always cover eyes when
working near batteries.
KEEP OUT OF REACH OF CHILDREN
APPLICATION RANGE
When using the generator, make sure the total load
is within rated output of a generator. Otherwise,
generator damage may occur.