Technical data: temperatures
Designation
Description
Ambient temperature
0 to 60 °C (32 ... 140 °F), standard
< 0 °C Use control air with low dew
point, protect valve stems from icing
up
Product temperature and operating
temperature
depending on the sealing material
Technical data: pressure
Designation
Description
Product pressure
max. 10 bar (145 psi), standard
Control air pressure
6 bar, max. 8 bar
Air requirement
13.1 cm
3
/stroke
Control air
acc. to ISO 8573-1
- Solid particle content:
Quality class 6
Particle size max. 5 µm
Particle density max. 5 mg/m
3
- Water content:
Quality class 4
max. dew point +3 °C
If the unit is used at higher altitudes or
at low ambient temperatures, the dew
point must be adapted accordingly.
- Oil content:
Quality class 3, ideally oil-free, max.
1 mg oil for 1 m
3
air
4.3
Resistance and permitted operating temperature of the sealing materials
The resistance and permitted operating temperature of the sealing materials
depend on the type and temperature of the medium conveyed. The exposure
time can adversely affect the service life of the seals. The sealing materials
comply with the regulations of FDA 21 CFR 177.2600 or FDA 21 CFR 177.1550.
The maximum operating temperature is defined by the sealing type and its
mechanical load.
Due to the versatile conditions of use (e.g. usage duration, switching frequency,
type and temperature of product and cleaning agents as well as usage
environment), GEA Tuchenhagen recommends that the user carries out
resistance tests.
Resistance:
•
+ = good resistance
•
o = reduced resistance
Technical data
Resistance and permitted operating temperature of the sealing materials