![GEA VARIVENT TSVN Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/gea/varivent-tsvn/varivent-tsvn_operating-instruction_4071178037.webp)
9.7
Installation
Assemble the valve in reverse order of disassembly. Observe the notes and
instructions given in the following sections when doing so.
9.7.1
O-Ring on the valve disk
Carry out the following steps:
1.
Fit the O-ring for the valve disk (7) without applying any grease.
–
Done.
9.7.2
Fitting the piston
Fig.12:
Fitting the piston
Carry out the following steps:
1.
Fit the piston (17) so that the recess points towards the lock washer (27).
®
Done.
9.7.3
Fitting position
The valve must be installed in vertically suspended position. This is the only
position in which the valve housing can reliably drain.
Maintenance