10.5.2 Removing the control top
Fig.27
Requirement:
•
No solenoid valve must be actuated electrically.
•
The pneumatic and electrical connections on the plant side can remain on the
control top.
Notice
The switch bar is sensitive and must be protected from impact
stress.
Damage to switch bar.
► Protect the switch bar against impact stress.
Tools required:
•
Hex socket key
•
Open-ended wrench
•
Slotted screwdriver
Carry out the following steps:
1.
Release the electrical connection (plug) from the proximity switch in the
lantern.
2.
Undo screws (39) with the inner hex socket key.
3.
Remove snap rings (15) from the control top (B).
4.
Remove the compressed air connections (Y2+Y3) on the lifting actuator.
5.
Pull the control top (B) upwards.
®
The feedback signal to the overriding control system is interrupted. The
green LED goes off and the red LED shines.
6.
Loosen the switching bar (1) with an open-ended wrench on the spanner flats
(1.1) and remove.
Maintenance
Disassembly
430BAL009261EN_2
60
17.04.2023
Содержание VARIVENT 24/7 PMO
Страница 6: ...430BAL009261EN_2 6 17 04 2023...
Страница 57: ...Fig 25 Requirement Maintenance Disassembly 430BAL009261EN_2 17 04 2023 57...
Страница 107: ...Appendix 430BAL009261EN_2 17 04 2023 107...
Страница 108: ......