No solenoid valve must be actuated electrically.
•
The pneumatic and electrical connections on the plant side can remain on the
control top.
Warning!
Spring tension in the valve
Danger of injury when detaching the clamp connection (43) as the released
spring pretension will suddenly lift the actuator.
► Therefore, release the spring tension before detaching the clamp
connection by pressurising the actuator with compressed air at max. 8 bar.
Tools required:
•
Open-ended wrench
•
Philips screwdriver
•
Slotted screwdriver
Maintenance
Disassembly
430BAL009261EN_2
58
17.04.2023