Fig.11
Warning!
Risk when actuating the valve, if there is fluid in the valve.
Fluids can leak or become mixed in the pipes.
► Ensure that there is no fluid in the valve.
Carry out the following steps:
1.
Connect the control air line to the control top T.VIS A-15 (connection P).
2.
Switch on the control top by connecting the power supply to the M12 plug
connector.
3.
Within 30 seconds after activation, press the two black buttons (A, B) on the
control button for 3 to 7 seconds at the same time.
®
The setup is carried out automatically. This process lasts approx. 90
seconds. Do not press any buttons during setup. Regardless of whether
and in what colours the LED shines or flashes.
®
As soon as the LED shines permanently green, the setup is completed
and the valve is operational.
Caution!
Changing the default settings of the control top
The default settings (signal damping / tolerance) of the control top are
changed by pressing the buttons during the setup.
► Do not press any buttons during the setup.
Hint!
In case of incorrect operation or when adjusting the default setting of
the control top, please refer to the operating instructions of the T.VIS
A-15
Assembly and installation
Electrical connection with T.VIS control top
430BAL009261EN_2
17.04.2023
37