Technical data: Ambient temperatures
Designation
Description
- Control top type T.VIS M-15, A-15
-20 to +50 °C (-4 ... +122 °F)
Product temperature and operating
temperature
depending on the sealing material
Technical data: Compressed air supply
Designation
Description
Air hose
- metric
Material PE-LD
Outside Ø 6 mm
Inside Ø 4 mm
- Inch
Material PA
Outside Ø 6.35 mm
Inside Ø 4.3 mm
Product pressure
max. 10 bar (145 psi)
Resistance to pressure surges*
From 11/ 2" OD
max. 50 bar
Control air pressure
6 bar, max. 8 bar (87 psi, max. 116
psi)
Control air
acc. to ISO 8573-1
- Solid particle content:
Quality class 6
Particle size max. 5 µm
Particle density max. 5 mg/m
3
- Water content:
Quality class 4 max. dew point +3 °C
If the unit is used at higher altitudes or
at low ambient temperatures, the dew
point must be adapted accordingly.
- Oil content:
Quality class 3,
preferably oil free,
max. 1 mg oil to 1 m
3
air
*Resistance to pressure surges in the closed state
5.3
Resistance and permitted operating temperature of the sealing materials
The resistance and permitted operating temperature of the sealing materials
depend on the type and temperature of the medium conveyed. The exposure
time can adversely affect the service life of the seals. The sealing materials
comply with the regulations of FDA 21 CFR 177.2600 or FDA 21 CFR 177.1550.
The maximum operating temperature is defined by the sealing type and its
mechanical load.
Technical data
Resistance and permitted operating temperature of the sealing materials
430BAL009261EN_2
28
17.04.2023
Содержание VARIVENT 24/7 PMO
Страница 6: ...430BAL009261EN_2 6 17 04 2023...
Страница 57: ...Fig 25 Requirement Maintenance Disassembly 430BAL009261EN_2 17 04 2023 57...
Страница 107: ...Appendix 430BAL009261EN_2 17 04 2023 107...
Страница 108: ......