The closed position of the lower seat is detected by a position measuring system.
The correct setting of this system, to detect the closed position of the lower seat,
can be found at Section 6.7, Page 36.
The sensitivity of the position measuring system is 0.1 mm.
The closed position of the upper seat is detected by the externally mounted
proximity switch S3 of the lantern. The correct setting of this initiator, to detect the
closed position of the upper seat, can be found at Section 6.7, Page 36.
The sensitivity of the position measuring system is also 0.1 mm.
Assembly and installation