97
Maintenance
Dismantling the Control Top into its Components
Fitting the Pneumatic Block
On ASEPTOMAG valves, special pneumatic block types must be used!
•
Pneumatic block T.VIS-15/NOT 3PV/ASG mat. no. 221-646.43
•
Pneumatic block T.VIS-15/ 3PV/ASG mat. no. 221-646.44
Pneumatic block (8.1) for max. 1 solenoid valve / pneumatic block (8.2) for max. 3 solenoid valves
Requirement:
Lightly grease the seals before fitting them to prevent them from falling out!
Carry out the following steps:
1.
Fit the pneumatic block in the reverse order.
Pneumatic block (8.2): first tighten screw (57.1), and then screw (57.2); tightening
torque 2 Nm.
2.
For fitting the other mounting parts (interface module, adapter module, solenoid
valves, control plate, logic element NOT), see the preceding pages.
Done.
NOTE
Fit the pneumatic block in the reverse order.
Lightly grease the seals before fitting them to prevent them from falling out!