73
Mounting the Control Top to Different Valves
Mounting to a Butterfly Valve T-smart 7 and a Mixproof Butterfly Valve T-smart 9
9.
Carry out commissioning, see chapter “Setting into Operation“ (page 50).
Done
Mounting to a Butterfly Valve T-smart 7 and a Mixproof
Butterfly Valve T-smart 9
Requirement:
Pay attention not to kink the air hoses when mounting the control top.
IMPORTANT NOTE
The permanent magnet on the switch bar is fragile.
Damage to the permanent magnet.
Protect the permanent magnet against impact stress.
IMPORTANT NOTE
Magnetic fields resulting from the permanent magnet on the switch bar.
Magnetic fields can delete data carriers and affect or destroy electronic or mechanical
components.
Protect the components against the magnetic fields from the switch bar.
Carry out the following steps:
1.
Screw the switch bar (1) into the actuator (A) and tighten using a mandrel (
Ø
6); tight-
ening torque 22 Nm.
2.
Fit the control top (B) over the switch bar (1) and on the actuator.
3.
Tighten the clamp connection (15) with screws (39) to a torque of 1 Nm.
4.
Align the pneumatic and electrical connections in accordance with the valve block
configuration.