81
Mounting the Control Top to Different Valves
Mounting to a T-smart Single-Seat and Double-Seal Valve
!
Internal air guiding is not possible on these valve types. Therefore connect the air
connection (Y1) on the control top to connection A4.2 on the actuator with an air
hose (L).
8.
Carry out commissioning, see chapter “Setting into Operation“ (page 50).
Done
Mounting to a T-smart Single-Seat and Double-Seal Valve
Requirement:
Pay attention not to kink the air hoses when mounting the control top.
IMPORTANT NOTE
The permanent magnet on the switch bar is fragile.
Damage to the permanent magnet.
Protect the permanent magnet against impact stress.
IMPORTANT NOTE
Magnetic fields resulting from the permanent magnet on the switch bar.
Magnetic fields can delete data carriers and affect or destroy electronic or mechanical
components.
Protect the components against the magnetic fields from the switch bar.
Carry out the following steps:
1.
Screw the switch bar (1) into the piston rod (A4.1) and tighten by applying an a/f 13
open end spanner at (1.1), tightening torque 2 Nm.
2.
Fit the control top (B) over the switch bar (1) and on the actuator (A.4).
3.
Tighten the clamp connection (15) and screws (39) to a torque of 1 Nm.