Safety
2.8
Unauthorised modifications and spare parts
No modifications or changes to the pump may be made without
the written approval of the manufacturer. In the interest of safety,
only original spare parts and accessories authorised by the
manufacturer may be used. The use of other parts can exempt
the manufacturer from liability for damage.
2.9
Improper operation
The operational reliability of the pump can be guaranteed only
when it is used properly, as indicated in the relevant sections of
the pump operating manual and the order papers.
The given limit values may not be exceeded under any circum-
stances.
2.10
Transport
Fig. 1:
Attachment points (example)
2.11
Cleaning
To ensure the quality of sensitive liquids, pumps must be cleaned
immediately after each use. Only this will remove adhesions and
sedimentary deposition and avoid the contamination of products.
To reach the best possible cleaning result, Hilge pumps are
optimised with regard to gaps and dead spaces. They are
designed in accordance with DIN EN 13951, and they are
resistant to the detergents mentioned below. The cleaning
happens inside the plant, without the need for disassembly or
removal of parts.
Generally, distinction is made between CIP and SIP. The
procedures must be based on state-of-the-art technology and
guidelines of the EC. In every case the user must make sure that
the cleaning and/or sterilisation processes used as well as the
operating temperature and operating steps meet the targets set
and are used for that purpose.
WARNING!
Tripping hazard from electric power cable!
▲
Death, serious bodily injury.
►
Route the electric power cable in such a way
that no one can trip over it (in case of porta-
ble pumps).
DANGER!
Electrical hazard!
▲
Death, serious bodily injury.
►
Use only approved electric cables and plugs.
WARNING
Falling loads!
▲
Death, serious bodily injury, damage to prop-
erty.
►
Transport work must only be performed by
appropriately qualified persons, and all safety
instructions must be observed.
►
Use suitable load carrying equipment with
sufficient capacity to transport the pump.
►
Make certain there are no persons under the
suspended load.
►
Make certain the pump is aligned horizontally
when it is lifted.
CAUTION!
Incorrect lifting points!
▲
Damage to property.
►
Fasten the rope to suitable lifting points.
►
Never fasten a rope to the pump housing or
suction/discharge port.
►
If pump is equipped with shroud, remove
shroud before transporting.
TM
05
2
2
82
47
12