6.4.2
Establishing the Compressed Air Supply
A prerequisite for the reliable operation of the valve is that the compressed air
hoses are cut exactly square.
Tools required:
•
A hose cutter
Carry out the following steps:
1.
Depressurize the pneumatic connection at the place where you are working.
2.
Use the hose cutter to cut the pneumatic hoses square.
3.
Connect a hose to the valve.
®
The compressed air supply has been established.
6.5
Electrical connections
Prerequisite:
•
The valve has been fitted correctly, see Section 10.6, Page 38.
Danger
Live parts
Electrical shock can result in serious personal injury or death.
► Only allow properly qualified staff to carry out work on the electrical
equipment.
► Prior to establishing electrical connections check the maximum
permissible operating voltage.
Explosive gases or dusts
An explosion can result in serious personal injury or death.
► Observe the installation and operating regulations for use in potentially
explosive areas.
Carry out the following steps:
1.
Connect in accordance with the control top diagram and the instructions in the
corresponding operating instructions for the T.VIS control top or other models.
®
The valve has been connected electrically.
Assembly and installation
Electrical connections
430BAL011547EN_2
26
08.07.2019