Compressed air supply
Compressed air supply
6 bar, compressed air filtered (at least 0,5 µm), oil-free.
Cleaning
Cleaning
The valve is suitable for CIP cleaning (Cleaning in Place)
Recommended cleaning speed
in the valve
At least 2 m/s
Sterilisation
Sterilisation
The valve is suitable for SIP sterilisation (Sterilisation in Place)
Sterilisation with
Hot water, max. 160 °C (320 °F)
Steam, max. 160 °C (320 °F)
Chemicals (e.g. H
2
O
2
)
Technical data
430BAL011547EN_2
22
08.07.2019