89
—
Installing indoor unit
Installing the connecting pipe
z
The flare end of the connecting pipe coincides with the flare
end connector of the corresponding valve.
z
Tighten the nut on the connecting pipe with strength and then
tighten it by spanner (as shown in right figure).
Note: Too great torque will damage the nut
Tightening torque is given as follows:
Hexagon nut(mm)
Tightening torque (N. m)
Distribution line connection
z
Remove the lifting handle on right-hand panel of the outdoor unit.
z
Remove the wire clip, connect and fix the Power connecting cord to terminals on the line bank,
and the wiring layout must be compatible with the indoor unit.
z
Use a wire clip to fix the power connecting cord for cooling &heating unit, the control line should
be fixed as well, and then connect the corresponding connectors.
z
Make sure wires have been fixed firmly.
z
Reassemble the lifting handle.
z
In case the power cord is not fitted with plug, the clearance between the electrodes of open
contact switch must not be less than 3 mm.
Note:
z
Wrong wiring connection will cause failure of some
electric components.
z
Do not pull the wires that are fixed by wire clip.
z
Do not connect the wires to outdoor unit with
excessive length allowance.
Loosen the screws, and remove the top cover.
Taping screw
Big handle
Fig. 11-10
Torque spanner
Spanner
Connecting pipe nut Connector
Fig. 11-9
Signal control
cable 2
×
0.75
Blue
Brown Yellow/green
Wire clamp
Power
connection cord
For heat pump only
Содержание PRO AIR 107
Страница 2: ... 1 Summary and features Model Remark PRO AIR 107 IN PRO AIR 107 OUT 1Ph 230V 50Hz R410A 1 ...
Страница 4: ... 3 Model Remark PRO AIR 218 IN PRO AIR 218 OUT 1Ph 230V 50Hz R410A ...
Страница 5: ... 4 Model Remark GE AIR 326 IN1 GE AIR 326 IN2 GE AIR 326 OUT 1Ph 230V 50Hz R407C ...
Страница 6: ... 5 Model Remark GE AIR 428 IN GE AIR 428 OUT 1Ph 230V 50Hz R407C ...
Страница 20: ... 19 4 2 Outline and installation dimensions of indoor unit 20 Handle 60cm Bolt Nut Spanner ...
Страница 21: ... 20 4 3 Outline and installation dimensions of indoor units 25 32 Handle Unit mm 500 Bolt Nut Spanner ...
Страница 71: ... 70 Explosive view and parts list Explosive view of parts and components of indoor unit 9 ...
Страница 75: ... 74 Explosive view of parts and components of outdoor unit ...
Страница 77: ... 76 Explosive view of parts and components of outdoor unit frequency converter ...
Страница 79: ... 78 Explosive view of parts of outdoor unit one driving two ...
Страница 81: ... 80 Explosive view of parts of outdoor unit one driving three ...
Страница 83: ... 82 Explosive view of parts of outdoor unit one driving four ...
Страница 101: ... 100 ...