—
41
—
Operation procedures/pictures
Disassembling panel body
Open the three taping screws fixing the panel
body with a screw driver. Pull upward the
panel body and then lift it backward to take out
the panel body.
As shown in Fig.8-4
Disassemble electric box cover
Press down the latches around the cover of
electric box to remove the cover of electric
box as shown in Fig.8-5.
Disassembling water-tray
Pull away the terminals of guide louver motor
and divide the lower right latch of the water
tray with a screw driver. Rotate the water tray
to disengage it from the side latch. Remove
the water tray as shown in Fig.8-5
Screw Panel body Screw Cover
Fig.8-4
Clamp
Fig.8-5
Clamp
Water-tray Connecting
terminal
Fig.8-6
Содержание PRO AIR 107
Страница 2: ... 1 Summary and features Model Remark PRO AIR 107 IN PRO AIR 107 OUT 1Ph 230V 50Hz R410A 1 ...
Страница 4: ... 3 Model Remark PRO AIR 218 IN PRO AIR 218 OUT 1Ph 230V 50Hz R410A ...
Страница 5: ... 4 Model Remark GE AIR 326 IN1 GE AIR 326 IN2 GE AIR 326 OUT 1Ph 230V 50Hz R407C ...
Страница 6: ... 5 Model Remark GE AIR 428 IN GE AIR 428 OUT 1Ph 230V 50Hz R407C ...
Страница 20: ... 19 4 2 Outline and installation dimensions of indoor unit 20 Handle 60cm Bolt Nut Spanner ...
Страница 21: ... 20 4 3 Outline and installation dimensions of indoor units 25 32 Handle Unit mm 500 Bolt Nut Spanner ...
Страница 71: ... 70 Explosive view and parts list Explosive view of parts and components of indoor unit 9 ...
Страница 75: ... 74 Explosive view of parts and components of outdoor unit ...
Страница 77: ... 76 Explosive view of parts and components of outdoor unit frequency converter ...
Страница 79: ... 78 Explosive view of parts of outdoor unit one driving two ...
Страница 81: ... 80 Explosive view of parts of outdoor unit one driving three ...
Страница 83: ... 82 Explosive view of parts of outdoor unit one driving four ...
Страница 101: ... 100 ...