background image

NX-591E 

15 

Loc 8 –13 When Phone Line Is Good 

 
 

Location 8  

Events To Report To Central Station 

(Phone line is good) 

16 segments of Feature Selection Data 

 

Reporting must be enabled in the control panel for this location to function 
properly. 

 

This location selects the partition(s) to include when reporting to the Central Station when the phone 
line is good. To exclude any partition from reporting, simply turn off the LED corresponding to that 
particular partition.  Using 

Table XI-1

 enter the corresponding number of the partition(s) to include for 

each type of report found in Segments 1 –16.  Factory default is all partitions OFF. 
 

SEGMENT DESCRIPTION  SEGMENT DESCRIPTION 

 

Alarms 

 

Tampers 

 

Open/Close 

10 

 

Short Circuit & Ground Fault 

 

Bypass 

11 

 

Sensor Lost 

 

Zone Trouble 

12 

 

Sensor Low Battery 

 

Power Trouble (AC Failure or 
Low Battery) 

13 

 

Expander Trouble 

 

Siren & Telephone Fault 

14 

 

Failure To Communicate 

 

Test Reports 

15 

 

Zone Activity Monitor 

 

Program, Download & Log Full 

16 

 

Reserved 

 
 

Location 9 

Special Events To Report To Central Station 

(Phone line is good) 

8 segments of Feature Selection Data 

 
This location selects the partition(s) to include when reporting Special Events to the Central Station 
when the phone line is good. To exclude any partition from reporting, simply turn off the LED 
corresponding to that particular partition.  Using 

Table XI-1

 on page 12, enter the corresponding 

number of the partition(s) to include for each type of report found in Segments 1 – 8.  Factory default 
is all partitions OFF. 
 

SEGMENT DESCRIPTION 

 

Alarm Restores 

 

Telephone Fault 

 

Start Download 

 

Fail to Communicate, Data Lost 

5-8 

Reserved 

 
 

Location 10  

Events To Report To Email 

(Phone line is good) 

16 segments of Feature Selection Data 

 

Reporting must be enabled in the control panel for this location to function 

properly. 

This location selects the partition(s) to include when reporting to email when the phone line is good. 
To exclude any partition from reporting, simply turn off the LED corresponding to that particular 
partition.  Using 

Table XI-1

 on page 12, enter the corresponding number of the partition(s) to include 

for each type of report found in Segments 1 –16.  Factory default is all partitions OFF 

Содержание NX-591E

Страница 1: ...NetworX Series NX 591E Cellemetry Module Installation and Startup...

Страница 2: ...TRUCTIONS 11 Location 0 Programming the Mode 11 Location 1 Feature Selection 11 Loc 2 7 When Phone Fault Is Detected 12 Location 2 Events To Report To Central Station 12 Location 3 Special Events To R...

Страница 3: ...essages to be reported keeping airtime to a minimum The NX 591E has 14 LEDs to provide extensive diagnostic and setup information II ACTIVATION VIA WEBSITE The cellemetry unit can be activated and man...

Страница 4: ...e that the insertion points have two sizes of holes a larger hole and a smaller hole Diagram 1 The black plastic PCB guides are grooved on one edge where the PC Board will be seated The end with the h...

Страница 5: ...ss takes about 12 seconds during which time the AService LED will illuminate When using the LCD Keypad the Service Required message will be displayed User codes will not be accepted during the enrolli...

Страница 6: ...et to tower Flashing Waiting for acknowledgement DS6 ON Sending data message to tower Flashing Waiting for acknowledgement XMIT Message packet being transmitted to tower POOR FAIR GOOD BEST The LEDs w...

Страница 7: ...NX 591E 7 IX CONNECTION DIAGRAM...

Страница 8: ...d 3 Factory Defaulting the Module The keypad will beep 3 times indicating that the loading is in progress Remember you will erase any values you may have entered previously 4 Programming a Location On...

Страница 9: ...ish The Armed LED will illuminate waiting for a new programming location to be entered To Review The Data location The Armed LED will flash If the location number is valid the Armed LED will extinguis...

Страница 10: ...nce the data is programmed press r to enter the data and advance to the next segment of that location After the last segment of a location is programmed pressing r will exit that location turn the Rea...

Страница 11: ...isable Cellular Service LEDs Disabled Enabled 7 Enable Tamper Switch Enabled Disabled 8 Disable SIA DCS Area Modifier Disabled Enabled Segment 2 programs for Host Acknowledgement requirements Factory...

Страница 12: ...GMENT DESCRIPTION 1 Alarms 9 Tampers 2 Open Close 10 Short Circuit Ground Fault 3 Bypass 11 Sensor Lost 4 Zone Trouble 12 Sensor Low Battery 5 Power Trouble AC Failure or Low Battery 13 Expander Troub...

Страница 13: ...pecial Events To Report To Email Phone fault detected 8 segments of Feature Selection Data This location selects the partition s to include when reporting Special Events to email To exclude any partit...

Страница 14: ...pecial Events To Report To Pager Phone fault detected 8 segments of Feature Selection Data This location selects the partition s to include when reporting Special Events to a pager To exclude any part...

Страница 15: ...ecial Events To Report To Central Station Phone line is good 8 segments of Feature Selection Data This location selects the partition s to include when reporting Special Events to the Central Station...

Страница 16: ...rtitions OFF SEGMENT DESCRIPTION 1 Alarm Restores 2 Telephone Fault 3 Start Download 4 Fail to Communicate Data Lost 5 8 Reserved Location 12 Events To Report To Pager Phone line is good 16 segments o...

Страница 17: ...ne is good To exclude any partition from reporting simply turn off the LED corresponding to that particular partition Using Table XI 1 on page 12 enter the corresponding number of the partition s to i...

Страница 18: ...ifier OFF 2 HOST ACKNOWLEGEMENT REQUIRED 1 Host Ack for Central Station messages OFF 2 Host Ack for email messages OFF 3 Host Ack for pager messages OFF 4 Host Ack for periodic test signals OFF 5 8 Re...

Страница 19: ...5 6 7 8 1 Alarms 2 Open Close 3 Bypass 4 Zone Trouble 5 Power Trouble AC Fail or Low Battery 6 Siren Telephone Fault 7 Test Reports 8 Program Download Log Full 9 Tampers 10 Short Circuit Ground Fault...

Страница 20: ...e Activity Monitor 16 Reserved 7 14 REPORTING SPECIAL EVENTS TO PAGER Phone line fault detected 1 2 3 4 5 6 7 8 1 Alarm Restores 2 Telephone Fault 3 Start Download 4 Fail to Communicate Data Lost 5 8...

Страница 21: ...6 7 8 1 Alarms 2 Open Close 3 Bypass 4 Zone Trouble 5 Power Trouble AC Fail or Low Battery 6 Siren Telephone Fault 7 Test Reports 8 Program Download Log Full 9 Tampers 10 Short Circuit Ground Fault 11...

Страница 22: ...6 Siren Telephone Fault 7 Test Reports 8 Program Download Log Full 9 Tampers 10 Short Circuit Ground Fault 11 Sensor Lost 12 Sensor Low Battery 13 Expander Trouble 14 Fail to Communicate 15 Zone Activ...

Страница 23: ...ne LED Horizontal Keypad NX 8E KIT NX 8E Control NX 108E Keypad 40VA Transformer NX 148E Alphanumeric LCD Keypad NX 8E KIT 8 NX 8E Control NX 1448E Keypad 40VA Transformer NX 1308E 8 Zone LED Door Des...

Страница 24: ...EDs enabled 90mA Max Transmission Burst 1 second 1300mA Max OPERATING TEMPERATURE 32 to 120 degrees F DIMENSIONS 2 40 Wide 4 40 High 1 20 Deep SHIPPING WEIGHT 1 lb Main Phone 800 727 2339 Technical Su...