NX-1710E Single Door Control
21
SEG
DESCRIPTION
5 LED2 (RED) OPTIONS
1
=
"On" to follow Armed status of system.
2 = "On" to toggle with the relay activation.
3 = "On" if inverted.
4-8 Reserved.
6-8 RESERVED
LOCATION 2 – X10 ADDRESS
1 MODULE NUMBER
0
=
Module 1
1 = Module 2
2 = Module 3
3 = Module 4
4 = Module 5
5 = Module 6
6 = Module 7
7 = Module 8
8 = Module 9
9 = Module 10
10 = Module 11
11 = Module 12
12 = Module 13
13 = Module 14
14 = Module 15
15 = Module 16
2 HOUSE CODE
0
=
A
1 = B
2 = C
3 = D
4 = E
5 = F
6 = G
7 = H
8 = I
9 = J
10 = K
11 = L
12 = M
13 = N
14 = O
15 = P
3 READER “A” SINGLE SCAN
0 = All units off
1 = All lights on
2 = On
3 = Off
4 = Dim
5 = Bright
6 = All lights off
7 = All others = Reserved
4 READER “A” TRIPLE SCAN
0 = All units off
1 = All lights on
2 = On
3 = Off
4 = Dim
5 = Bright
6 = All lights off
7 = All others = Reserved
5 READER “B” SINGLE SCAN
0 = All units off
1 = All lights on
2 = On
3 = Off
4 = Dim
5 = Bright
6 = All lights off
7 = All others = Reserved
6 READER “B” TRIPLE SCAN
0 = All units off
1 = All lights on
2 = On
3 = Off
4 = Dim
5 = Bright
6 = All lights off
7 = All others = Reserved
LOCATION 3 – OPTIONS & DOOR CONTROL PARTITION
1 UNIT OPTIONS
1 =
"On" if enabled for User Card Programming
2 =
"On" if tamper enabled
3 =
"On" if on-board zone is disabled
4 =
Reserved.
5 =
“On” if an RTE from a scanned card is to be logged as Code Entry
6 =
“On” if an RTE from a zone or the egress input is to be logged as Code Entry
7-8 =
Reserved
2 DOOR OPTIONS
1 =
"On" if locking mechanism is a Maglock or Drop Bolt.
2 =
"On" if access is allowed regardless of Armed status of the system.
3 =
"On" if the door is not to be latched unlocked during an open schedule.
4 =
"On" if onboard relay only triggers during an open schedule.
5 =
“On” if onboard relay only triggers during a close schedule.
6 =
“On” if Forced Entry Alarm is logged.
7 =
“On” if access allowed without an RTE.
8 =
“On” if relay operates normally during off-schedule (
outside of regular operating hours
).
3 ENABLING THE SCHEDULES FOR THE ONBOARD RELAY
1 =
"On" if driver follows Schedule 1.
2 =
"On" if driver follows Schedule 2.
3 =
"On" if driver follows Schedule 3.
4 =
"On" if driver follows Schedule 4.
5 =
"On" if driver follows Schedule 5.
6 =
"On" if driver follows Schedule 6.
7 =
"On" if driver follows Schedule 7.
8 =
"On" if driver follows Schedule 8.
4 READER PARTITION
1 =
"On" if door control is in Partition 1
2 =
"On" if door control is in Partition 2
3 =
"On" if door control is in Partition 3
4 =
"On" if door control is in Partition 4
5 =
"On" if door control is in Partition 5
6 =
"On" if door control is in Partition 6
7 =
"On" if door control is in Partition 7
8 =
"On" if door control is in Partition 8