NX-1710E Single Door Control
20
Tip:
Defaults are shown in bold italics.
IX.
PROGRAMMING WORKSHEETS
SEG
DESCRIPTION
LOCATION 0 – READER “A” SCAN FUNCTIONS & OPTIONS
1 SINGLE SCAN FUNCTION
1 = "On" to send Code Entry function to the control panel.
2 = "On" to activate the Armed Away mode.
3 = "On" to activate the Armed Stay mode.
4 = "On" to send the Disarm function to the control panel.
5 = "On" to send Auxiliary Function #1 to the control panel.
6 = "On" to send Auxiliary Function #2 to the control panel.
7 = "On" to broadcast an X-10 function (see Location 2).
8 = "On" to send a Request To Exit (RTE); and activate the onboard relay
2 TRIPLE SCAN FUNCTION
1
=
"On" to send Code Entry function to the control panel.
2 = "On" to activate the Armed Away mode.
3 = "On" to activate the Armed Stay mode.
4 = "On" to send the Disarm function to the control panel.
5 = "On" to send Auxiliary Function #1 to the control panel.
6 = "On" to send Auxiliary Function #2 to the control panel.
7 = "On" to broadcast an X-10 function (see Loc 2).
8 = "On" to send an RTE & activate the onboard relay.
3 READER OPTIONS
1 = "On" if tamper is inverted.
2 = "On" if tamper is enabled.
3 = "On" if reader buzzer is to follow typical keypad buzzing.
4 = “On" if reader automatically issues a beep when a card is scanned.
5-8 Reserved.
4 LED1 (GREEN) OPTIONS
1
=
"On" to follow Ready status of system.
2 = "On" to toggle with the relay activation.
3 = "On" if inverted.
5-8
Reserved.
5 LED2 (RED) OPTIONS
1
=
"On" to follow Armed status of system.
2 = "On" to toggle with the relay activation.
3 = "On" if inverted.
4-8 Reserved.
6-8 RESERVED
LOCATION 1 – READER “B” SCAN FUNCTIONS & OPTIONS
1 SINGLE SCAN FUNCTION
1 = "On" to send Code Entry function to the control panel.
2 = "On" to activate the Armed Away mode.
3 = "On" to activate the Armed Stay mode.
4 = "On" to send the Disarm function to the control panel.
5 = "On" to send Auxiliary Function #1 to the control panel.
6 = "On" to send Auxiliary Function #2 to the control panel.
7 = "On" to broadcast an X-10 function (see Location 2).
8 = "On" to send a Request To Exit (RTE); and activate the onboard relay.
2 TRIPLE SCAN FUNCTION
1
=
"On" to send Code Entry function to the control panel.
2 = "On" to activate the Armed Away mode.
3 = "On" to activate the Armed Stay mode.
4 = "On" to send the Disarm function to the control panel.
5 = "On" to send Auxiliary Function #1 to the control panel.
6 = "On" to send Auxiliary Function #2 to the control panel.
7 = "On" to broadcast an X-10 function (see Loc 2).
8 = "On" to send an RTE & activate the onboard relay.
3 READER OPTIONS
1 = "On" if tamper is inverted.
2 = "On" if tamper is enabled.
3 = "On" if reader buzzer is to follow typical keypad buzzing.
4 = “On" if reader automatically issues a beep when a card is scanned.
5 = “On” if LEDs to extinguish after 2 minutes without a scan.
6-8 Reserved.
4 LED1 (GREEN) OPTIONS
1
=
"On" to follow Ready status of system.
2 = "On" to toggle with the relay activation.
3 = "On" if inverted.
4-8 Reserved.