NX-6V2 Control
29
166
ZONE TYPE 29 ALARM EVENT CODE
1............. numerical
Location 166 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on
page 43. The zone ID will be that zone that is in alarm. If 4+2 format is being used, refer to Location 110 on page 25 for details.
167
ZONE TYPE 29 CHARACTERISTIC SELECT
5............. feature select
Use "Zone Type Characteristic Selections" described in Location 111, page 25
168
ZONE TYPE 30 ALARM EVENT CODE
1............. numerical
Location 168 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on
page 43. The zone ID will be that zone that is in alarm. If 4+2 format is being used, refer to Location 110 on page 25 for details.
169
ZONE TYPE 30 CHARACTERISTIC SELECT
5............. feature select
Use "Zone Type Characteristic Selections" described in Location 111, page 25
170-205
RESERVED
206
AUTO DISARM DAY SELECTION
8............. feature select
Location 206 selects which days each partition will auto disarm. Segment 1 is for partition 1, and segment 2 is for partition 2. If a zone
is faulted when the panel tries to auto disarm, the zone will be bypassed.
Segments 1-2:
1 = Auto Disarming on Sunday.
2 = Auto Disarming on Monday.
3 = Auto Disarming on Tuesday.
4 = Auto Disarming on Wednesday.
5 = Auto Disarming on Thursday.
6 = Auto Disarming on Friday.
7 = Auto Disarming on Saturday.
8 = Reserved.
Содержание NetworX NX-6V2
Страница 5: ...NX 6V2 Control 5 IV WIRING DIAGRAM ...
Страница 30: ...30 NX 6V2 Control NOTES ...
Страница 51: ......